Objective: To assess the repeatability of infrared thermometer temperature readings and evaluate the correlation between digital rectal temperature and infrared thermometer temperatures taken at different locations in healthy afebrile horses.
Animals: 101 afebrile horses ≥ 1 year old.
Methods: Digital rectal temperatures and infrared temperatures from the eye, gingiva, neck, axilla, and perineum were obtained in a climate-controlled environment and at 2 outdoor ambient temperatures (study period, November 1, 2021, to April 30, 2023).
Results: Infrared temperature measurements were well tolerated by horses, including those resistant to rectal temperature. There was significant correlation between rectal temperature and infrared temperature taken at the perineum (R = 0.57; P < .001) and eye (R = 0.37; P < .001). Infrared temperature measurements were highly repeatable, allowing for calculation of reference ranges for the perineum (36.0 to 37.8 °C) and eye (35.7 to 37.1 °C) in climate-controlled conditions. There was increased variance in outside temperatures compared to climate-controlled conditions for the eye (P = .002), gingiva (P = .047), and perineum (P = .005).
Clinical Relevance: While infrared thermometer temperatures were not numerically the same as rectal temperature using a digital thermometer, measurements at the perineum and eye were correlated with rectal temperature readings. Further, the repeatability of infrared readings allows for computation of reference ranges that make the infrared thermometer a viable alternative for the practicing veterinarian when obtaining a temperature in uncooperative horses. The infrared thermometer was reliable outdoors for the eye, but not the perineum. Additional validation of infrared temperature reference ranges in febrile horses and warmer ambient temperatures is warranted.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2460/javma.23.12.0714 | DOI Listing |
RSC Adv
January 2025
Department of Condensed Matter Physics, GdS Optronlab, LUCIA Building, University of Valladolid Paseo de Belén 19 47011 Valladolid Spain.
Luminescent materials doped with rare-earth (RE) ions have emerged as powerful tools in thermometry, offering high sensitivity and accuracy. However, challenges remain, particularly in maintaining efficient luminescence at elevated temperatures. This study investigates the thermometric properties of BiVO: Yb/Er (BVO: Er/Yb) nanophosphors synthesized the sol-gel method.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Department of Physical Therapy, Faculty of Health Sciences, University of Granada (UGR), 18071 Granada, Spain.
The aim of this study was to analyze the association between circulating amino acids and central and peripheral body temperature in subjects with and without fibromyalgia syndrome (FMS). A total of 47 patients with FMS and 59 healthy subjects were included in the study. The concentration of amino acids was determined in serum samples using a fluorimeter coupled with a high-performance liquid chromatography system.
View Article and Find Full Text PDFCells
December 2024
Institute of Solid State Physics, Bulgarian Academy of Sciences, Tzarigradsko Chaussee 72, 1784 Sofia, Bulgaria.
Laser-induced photothermal therapy using gold nanoparticles (AuNPs) has emerged as a promising approach to cancer therapy. However, optimizing various laser parameters is critical for enhancing the photothermal conversion efficacy of plasmonic nanomaterials. In this regard, the present study investigates the photothermal effects of dodecanethiol-stabilized hydrophobic ultrasmall spherical AuNPs (TEM size 2.
View Article and Find Full Text PDFBMC Infect Dis
January 2025
School of Nursing, China Medical University, 100, Sec. 1, Jingmao Rd, Taichung, 406040, Taiwan.
Background: Non-invasive temporal artery thermometers (TATs) and non-contact infrared thermometers (NCITs) are increasingly used in community settings to measure body temperature. Existing research predominantly focuses on pediatric populations, yet the accuracy and precision of TATs and NCITs for fever screening across age groups remain unclear. This study aims to assess age-related differences in the diagnostic accuracy of TATs and NCITs for fever detection.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China.
Fluorescence thermometry based on metal halide perovskites is increasingly becoming a hotspot due to its advantages of high detection sensitivity, noninvasiveness, and fast response time. However, it still presents certain technical challenges in practical applications, such as complex synthesis methods, the use of toxic solvents, and being currently mainly based on the visible/first near-infrared light with poor penetration and severe autofluorescence. In this study, we synthesize the second near-infrared (NIR-II) luminescent crystals based on Yb/Nd-doped zero-dimensional CsScCl·HO by a simple "dissolve-dry" method.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!