A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analytical quality by design approach for the development of high-performance liquid chromatography method for simultaneous analysis of metformin and sitagliptin in the presence of major degradation products. | LitMetric

An analytical quality by design-based high-performance liquid chromatography method for determining metformin (MET) and sitagliptin (SIT) in stress-degraded samples was developed and validated. The analytical target profile and risk assessment-driven critical method variables, for example, pH, % aqueous, and buffer concentration, were studied for their effect on method responses of retention time and resolution using a central composite design. The correlation regression coefficient was more than 0.8, and variables interaction was significant on method responses with curvature effect. The method operable design region afforded an aqueous range of 55%-70% and an ortho-phosphoric acid buffer of 0.1% with a pH of 3.0-4.0 as a robust region for the suitable method performance characteristics. The separation of MET and SIT from their degradants (m/z 85.0509; m/z 193.0694) on the C column was achieved using a mobile phase consisting of 0.1% ortho-phosphoric acid and methanol (60:40% v/v; pH 3.0). The optimized method eluted MET and SIT at 4.3 ± 0.2 and 7.1 ± 0.2 min, respectively, with acceptable specificity and resolution. The linearity ranges of 25-250 μg/mL (r : 0.9982) and 5-50 μg/mL (r : 0.9989) was established for MET and SIT, respectively. The % recovery (98.81%-102.17%), precision (0.55%-1.65%), and robustness study for method variables were acceptable.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.202300605DOI Listing

Publication Analysis

Top Keywords

met sit
12
method
9
analytical quality
8
high-performance liquid
8
liquid chromatography
8
chromatography method
8
method variables
8
method responses
8
ortho-phosphoric acid
8
quality design
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!