Design and construction of a refrigerator-cooled adiabatic calorimeter for heat capacity measurement in liquid helium temperature region.

Rev Sci Instrum

Thermochemistry Laboratory, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian Technology Innovation Center for Energy Materials Thermodynamics, Liaoning Province Key Laboratory of Thermochemistry for Energy and Materials, Dalian National Laboratory for Clean Energy, Dalian 116023, People's Republic of China.

Published: March 2024

Heat capacity is a fundamental thermodynamic property of a substance. Although heat capacity values and related thermodynamic functions are available for many materials, low-temperature heat capacity measurements, especially for novel materials, can still provide valuable insights for research in physics, chemistry, thermodynamics, and other fields. Reliable low-temperature heat capacity data are typically measured using classical adiabatic calorimeters, which use liquid helium as the refrigerant to provide a cryogenic environment for heat capacity measurements. However, liquid helium is not only expensive but also not easy to obtain, which greatly limits the application of adiabatic calorimetry. In this work, an accurate adiabatic calorimeter equipped with a Gifford-MacMahon refrigerator was designed and constructed for measuring the heat capacity of condensed matter in the temperature range from 4 to 100 K. The Gifford-MacMahon refrigerator was utilized to provide a stable liquid helium-free cryogenic environment. A simple mechanical thermal switch assembly was designed to facilitate switching between the refrigeration mode and the adiabatic measurement mode of the calorimeter. Based on the measurement results of standard reference materials, the optimized repeatability and accuracy of heat capacity measurements were determined to be within 0.8% and 1.5%, respectively. The heat capacity of α-Fe2O3 nanoparticles was also investigated with this device. Furthermore, this adiabatic calorimeter only requires electricity to operate in the liquid helium temperature range, which may significantly advance the research on low-temperature heat capacity based on adiabatic calorimetry.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0159807DOI Listing

Publication Analysis

Top Keywords

heat capacity
40
liquid helium
16
adiabatic calorimeter
12
low-temperature heat
12
capacity measurements
12
heat
10
capacity
10
helium temperature
8
cryogenic environment
8
adiabatic calorimetry
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!