Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5543/tkda.2023.30497 | DOI Listing |
BMC Cardiovasc Disord
January 2025
Department of Hematology and Oncology, Shenzhen Children's Hospital of China Medical University, Shenzhen, 518038, China.
Purpose: Pacemaker-related infections are serious complications of cardiac implantable electronic devices (CIEDs). This case report aims to describe the occurrence of pacemaker pocket infection and recurrent ventricular tachycardia (VT) in a Chinese amateur violinist with sick sinus syndrome (SSS), and to explore the possible connection between occupational habits and the infection, as well as VT.
Methods: A 76-year-old male violinist with a Biotronik Evia DR dual-chamber pacemaker presented with syncope and signs of a pacemaker pocket infection three years after implantation.
Eur Heart J Case Rep
January 2025
1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland.
Background: Transvenous lead extraction (TLE) has become an essential component of lead management strategies, but it carries the risk of severe complications, including damage to the tricuspid valve. Currently, there are no established predictors that can help prevent these complications.
Case Summary: An 84-year-old male with a dual-chamber pacemaker was admitted to the hospital due to a pocket fistula resulting from a local infection.
Strahlenther Onkol
January 2025
TUM School of Medicine and Health, Department of Radiation Oncology, Technische Universität München (TUM), Klinikum rechts der Isar, Munich, Germany.
Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.
View Article and Find Full Text PDFBMC Cardiovasc Disord
December 2024
Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China.
Background: Delayed lead perforation is a rare complication of cardiac implantable electronic device (CIED). Clinical presentations range from completely asymptomatic to pericardial tamponade. Surgical lead extraction is recommended and transvenous lead extraction (TLE) with surgical backup is an alternative method.
View Article and Find Full Text PDFFoods
November 2024
College of Food Science and Engineering, Qingdao Agricultural University, Qingdao 266109, China.
Utilizing (), this study constructed a dual-chamber microbial electrosynthesis system, based on microbial electrolysis cells, that was capable of producing lycopene. Cultivation within the electrosynthesis chamber yielded a lycopene concentration of 282.3722 mg/L when the optical density (OD) reached 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!