Polar coordinate active-matrix digital microfluidics for high-resolution concentration gradient generation.

Lab Chip

CAS Key Laboratory of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88 Keling Road, Suzhou, Jiangsu Province, 215163, P. R. China.

Published: April 2024

Automated concentration gradient generation is one of the most important applications of lab-on-a-chip devices. Digital microfluidics is a unique platform that can effectively achieve digitalized gradient concentration preparation. However, the dynamic range and concentration resolution of the prepared samples heavily rely on the size and the number of effective electrodes. In this work, we report an active-matrix digital microfluidic device with polar coordinate electrode arrangement. The device contains 33 different electrode sizes, generating digital droplets of different volumes. To compare with the conventional rectangular coordinate arrangement with a similar electrode number, this work shows an approximately 19 times resolution enhancement for the achievable concentration gradient. We characterized the stability and uniformity of droplets generated by electrodes of different sizes, and the coefficient of variation of stable droplets was less than 3%. The fluorescent nanomaterial's concentration quantification and glucose concentration characterization experiments were also conducted, and the correlation coefficients for the linearities were all above 0.99.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3lc00979cDOI Listing

Publication Analysis

Top Keywords

concentration gradient
12
polar coordinate
8
active-matrix digital
8
digital microfluidics
8
gradient generation
8
concentration
7
coordinate active-matrix
4
digital
4
microfluidics high-resolution
4
high-resolution concentration
4

Similar Publications

Spatially dependent tissue distribution of thyroid hormones by plasma thyroid hormone binding proteins.

Pflugers Arch

January 2025

Gangarosa Department of Environmental Health, Rollins School of Public Health, Emory University, Atlanta, GA, 30322, USA.

Plasma thyroid hormone (TH) binding proteins (THBPs), including thyroxine-binding globulin (TBG), transthyretin (TTR), and albumin (ALB), carry THs to extrathyroidal sites, where THs are unloaded locally and then taken up via membrane transporters into the tissue proper. The respective roles of THBPs in supplying THs for tissue uptake are not completely understood. To investigate this, we developed a spatial human physiologically based kinetic (PBK) model of THs, which produces several novel findings.

View Article and Find Full Text PDF

A Simple and Sensitive LC-MS/MS Method for the Determination of Mobocertinib and Its Metabolite Desmethyl-Mobocertinib in Human Plasma and Its Application to Clinical Pharmacokinetic Study.

Biomed Chromatogr

February 2025

Yangzhou University Medical College, Jiangsu Key Laboratory of Experimental & Translational Non-coding RNA Research, Institute of Translational Medicine, Yangzhou University, Yangzhou, Jiangsu Province, China.

Mobocertinib is a potent selective tyrosine kinase inhibitor approved for the treatment of non-small cell lung cancer with activating EGFR exon 20 insertions. The aim of this study was to develop a procedure for liquid chromatography tandem mass spectrometry (LC-MS/MS) for the determination of mobocertinib and its metabolite desmethyl-mobocertinib in human plasma. The human plasma samples were precipitated with acetonitrile and analyzed using a Waters ACQUITY BEH C column coupled to a triple quadrupole mass spectrometer.

View Article and Find Full Text PDF

Liquid Chromatography Combined With Tandem Mass Spectrometry for the Pharmacokinetic and Metabolism Studies of PROTAC ARV-471 in Rats.

Biomed Chromatogr

February 2025

Department of Breast and Thyroid Surgery, The First Affiliated Hospital of University of Science and Technology of China, Anhui Provincial Hospital, Hefei, Anhui Province, China.

Proteolysis targeting chimera (PROTAC) is emerging as a promising medicinal modality, which has aroused widespread interest among the field of pharmaceutical manufacturing in the recent years. ARV-471 is an orally active PROTAC estrogen receptor degrader against breast cancer, which leads to the ubiquitylation and subsequent degradation of estrogen receptors via the proteasome. In this study, we developed a highly sensitive liquid chromatography tandem mass spectrometry method (LLOQ = 0.

View Article and Find Full Text PDF

A new selective and sensitive high-performance liquid chromatography (HPLC) method was developed for the quantification of potential impurities in fluoxetine hydrochloride. Chromatographic separation was achieved on an end-capped octadecylsilyl silica gel (Gemini-C18 150 mm × 4.6 mm, 3.

View Article and Find Full Text PDF

The pervasive model for a solvated, ion-filled nanopore is often a resistor in parallel with a capacitor. For conical nanopore geometries, here we propose the inclusion of a Warburg-like element, which is necessary to explain otherwise anomalous observations such as negative capacitance and low-pass filtering of translocation events (we term this phenomenon as Warburg filtering). The negative capacitance observed here has long equilibration times and memory (that is, mem-capacitance) at negative voltages.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!