A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Facile NMR Method for Pre-MRI Evaluation of Trigger-Responsive T Contrast Enhancement. | LitMetric

There is a growing interest in developing paramagnetic nanoparticles as responsive magnetic resonance imaging (MRI) contrast agents, which feature switchable T image contrast of water protons upon biochemical cues for better discerning diseases. However, performing an MRI is pragmatically limited by its cost and availability. Hence, a facile, routine method for measuring the T contrast is highly desired in early-stage development. This work presents a single-point inversion recovery (IR) nuclear magnetic resonance (NMR) method that can rapidly evaluate T contrast change by employing a single, optimized IR pulse sequence that minimizes water signal for "off-state" nanoparticles and allows for sensitively measuring the signal change with "switch-on" T contrast. Using peptide-induced liposomal gadopentetic acid (Gd-DTPA) release and redox-sensitive manganese oxide (MnO) nanoparticles as a demonstration of generality, this method successfully evaluates the T shortening of water protons caused by liposomal Gd-DTPA release and Mn formation from MnO reduction. Furthermore, the NMR measurement is highly correlated to T-weighted MRI scans, suggesting its feasibility to predict the MRI results at the same field strength. This NMR method can be a low-cost, time-saving alternative for pre-MRI evaluation for a diversity of responsive T contrast systems.

Download full-text PDF

Source
http://dx.doi.org/10.1002/smtd.202301603DOI Listing

Publication Analysis

Top Keywords

nmr method
12
pre-mri evaluation
8
magnetic resonance
8
water protons
8
gd-dtpa release
8
contrast
7
method
5
facile nmr
4
method pre-mri
4
evaluation trigger-responsive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!