NT-proBNP detection with a one-step magnetic lateral flow channel assay.

Anal Bioanal Chem

Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053, Regensburg, Germany.

Published: April 2024

Point-of-care sensors targeting blood marker analysis must be designed to function with very small volumes since acquiring a blood sample through a simple, mostly pain-free finger prick dramatically limits the sample size and comforts the patient. Therefore, we explored the potential of converting a conventional lateral flow assay (LFA) for a significant biomarker into a self-contained and compact polymer channel-based LFA to minimize the sample volume while maintaining the analytical merits. Our primary objective was to eliminate the use of sample-absorbing fleece and membrane materials commonly present in LFAs. Simultaneously, we concentrated on developing a ready-to-deploy one-step LFA format, characterized by dried reagents, facilitating automation and precise sample transport through a pump control system. We targeted the detection of the heart failure biomarker NT-proBNP in only 15 µL human whole blood and therefore implemented strategies that ensure highly sensitive detection. The biosensor combines streptavidin-functionalized magnetic beads (MNPs) as a 3D detection zone and fluorescence nanoparticles as signal labels in a sandwich-based immunoassay. Compared to the currently commercialized LFA, our biosensor demonstrates comparable analytical performance with only a tenth of the sample volume. With a detection limit of 43.1 pg∙mL and a mean error of 18% (n ≥ 3), the biosensor offers high sensitivity and accuracy. The integration of all-dried long-term stable reagents further enhances the convenience and stability of the biosensor. This lateral flow channel platform represents a promising advancement in point-of-care diagnostics for heart failure biomarkers, offering a user-friendly and sensitive platform for rapid and reliable testing with low finger-prick blood sample volumes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10973066PMC
http://dx.doi.org/10.1007/s00216-024-05223-xDOI Listing

Publication Analysis

Top Keywords

lateral flow
12
flow channel
8
blood sample
8
sample volume
8
heart failure
8
sample
6
nt-probnp detection
4
detection one-step
4
one-step magnetic
4
magnetic lateral
4

Similar Publications

Rapid and sensitive detection of Epstein-Barr virus cell-free DNA (EBV cfDNA) is crucial for early diagnosis and monitoring of nasopharyngeal carcinoma (NPC), but accessibility to screening is limited by complicated and costly conventional DNA isolation and purification approaches. Here, a fully integrated ion concentration polarization (ICP)-enriched and nanozyme-catalyzed lateral flow assay (ICP-cLFA) is developed, enabling total analysis of EBV cfDNA in whole blood samples, with DNA isolation, pre-concentration, and amplification performed on a microfluidic chip, consequently providing the signal readout within 75 min. Specifically, ICP preconcentration and amplification steps, together with target recognition catalyzed by a platinum-decorated mesoporous gold nanosphere (MGNS@Pt) nanozyme, result in an ultralow detection limit of 4 aM in standard cfDNA samples and 100 aM in whole blood from NPC-bearing rats.

View Article and Find Full Text PDF

This differential extraction protocol details the steps for isolating DNA from sample pads used in lateral flow immunochromatographic (LFI) tests, particularly for cases involving mixed biological samples such as semen and menstrual blood, or other evidence related to sexual assault. This procedure utilizes a differential extraction technique applied to sample pads from immunochromatographic tests, where the sample pads serve as the substrate. The method involves two sequential lysis steps to effectively separate non-sperm and sperm fractions, enabling the targeted isolation of distinct cell types for downstream DNA analysis.

View Article and Find Full Text PDF

Objective: The objective of this study is to compare the effectiveness of low-load blood flow restriction training (LL-BFRT) to heavy-load resistance training (HL-RT) in male collegiate athletes with chronic non-specific low back pain (CNLBP).

Methods: Twenty-six participants were randomly assigned to LL-BFRT ( = 13) or HL-RT ( = 13). All participants supervised exercises (deep-squat, lateral pull-down, bench-press and machine seated crunch) cycled 4 times per week for 4 weeks (16 sessions).

View Article and Find Full Text PDF

This research presents a numerical study over the unsteady natural convection of an electrically conducting fluid in an open-ended vertical parallel plate microchannel under uniform and asymmetric heat flux subjected to a uniform lateral magnetic field. Slip velocity, as well as temperature jump at channel walls, are modeled using a first-order model. The effects of Knudsen number)(, heat flux ratio)rq(, Grashof number)(, and Hartmann number)M(on mass flow rate, the maximum temperature of the wall, and average Nusselt () as a function of time are discussed.

View Article and Find Full Text PDF

Use of Lung Volume Recruitment Technique in Patients With Chronic Respiratory Disease Among Brazilian Health Professionals.

Pulm Med

January 2025

Post Graduation Department, Escola Superior de Ciências da Saúde (ESCS), Brasilia, Distrito Federal, Brazil.

Lung volume recruitment (LVR) is a stacked-breath assisted inflation technique in which consecutive insufflations are delivered, without exhaling in between, until the maximum tolerable inflation capacity is reached. Although LVR is recommended in some neuromuscular disease guidelines, there is little information detailing when and how allied health professionals (AHPs) prescribe LVR. This study is aimed at describing the use of LVR in practice across Brazil.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!