Purpose: The impact of the COVID-19 pandemic on antimicrobial resistance (AMR) is largely studied in healthcare settings. There is a need to understand the fluctuations in AMR during pandemic at the community level. With urinary tract infection (UTI) being one of the most common infections in the community, the AMR profile of community-acquired UTI (CA-UTI) is considered representative AMR at the community level.

Methods: The study was taken in a cohort of patients with a clinical diagnosis of CA-UTI. The four study sites represented different community health centres in India. Escherichia coli isolates were analysed phenotypically and genotypically for AMR pre-COVID (October 2019-February 2020) and in the first (March 2020-February 2021) and second waves of COVID-19 (March 2021-December 2021).

Results: E. coli was the predominant uropathogen (229, 82%). Increased susceptibility to nitrofurantoin was observed during the pandemic. Reduced susceptibility to first-line oral antibiotics and carbapenems was seen during the second wave, and an increased minimum inhibitory concentration (MIC) to beta-lactams and fluoroquinolones was seen during the pandemic. Genomic analysis of E. coli isolates showed some AMR genes (aacC1, aacC4, SHV, QepA) only during the second wave.

Conclusion: One good outcome of the pandemic was increased susceptibility to nitrofurantoin, while drawback was a significant decrease in susceptibility to oral antibiotics during the second wave and increased MIC of some antibiotics. Decreased susceptibility to last-resort carbapenems and the occurrence of various AMR genes during the second wave of the pandemic are of great concern.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jgar.2024.02.022DOI Listing

Publication Analysis

Top Keywords

second wave
12
antimicrobial resistance
8
escherichia coli
8
urinary tract
8
tract infection
8
covid-19 pandemic
8
coli isolates
8
increased susceptibility
8
susceptibility nitrofurantoin
8
oral antibiotics
8

Similar Publications

Resonant Conversion of Wave Dark Matter in the Ionosphere.

Phys Rev Lett

December 2024

Departement de Physique Theorique, Universite de Geneve, 24 quai Ernest Ansermet, 1211 Geneve 4, Switzerland.

We consider resonant wavelike dark matter conversion into low-frequency radio waves in the Earth's ionosphere. Resonant conversion occurs when the dark matter mass and the plasma frequency coincide, defining a range m_{DM}∼10^{-9}-10^{-8}  eV where this approach is best suited. Owing to the nonrelativistic nature of dark matter and the typical variational scale of the Earth's ionosphere, the standard linearized approach to computing dark matter conversion is not suitable.

View Article and Find Full Text PDF

Research on hydrodynamic performance of S-type turbine based on linear wave.

PLoS One

January 2025

Faculty of Mechanical Engineering & Mechanics, Ningbo University, Ningbo, Zhengjiang, China.

The hydrodynamic performance of a Savonius type turbine (S-type turbine) in wave field is studied. The method of combining numerical simulation with physical experiment is adopted.Based on linear wave theory and turbulence model, Star CCM+numerical simulation software is used for digital modeling, and overlapping grid technology is used for grid modeling.

View Article and Find Full Text PDF

Objective:  This study compares the color change of non-vital anterior teeth after laser-activated bleaching and conventional walking bleaching technique.

Materials And Methods:  Sixty extracted teeth were endodontically treated, stained in a black tea solution, and the baseline shade was measured using a spectrophotometer (Easyshade, VITA). Bleaching was done using either: internal bleaching with 35% HO (Opalescence Endo) and then tooth sealed for 5 days (Gr1), 35% HO (JW Next) for 7 minutes (Gr2), internal and external bleaching for 7 minutes (Gr3), diode laser-activated internal bleaching for 30 seconds (940 nm, continuous wave, 2 W, noncontact mode, 300 um, non-initiated tip), wait for 7 minutes, second laser application for 30 seconds, tooth sealed for 5 days (Gr4), diode laser-activated internal bleaching for 24 hours (Gr5), or diode laser-activated internal and external bleaching for 24 hours (Gr6) ( = 10).

View Article and Find Full Text PDF

A (target) quantum system is often measured through observations performed on a second (meter) system to which the target is coupled. In the presence of global conservation laws holding on the joint meter-target system, the Wigner-Araki-Yanase theorem and its generalizations predict a lower bound on the measurement's error (Ozawa's bound). While practically negligible for macroscopic meters, it becomes relevant for microscopic ones.

View Article and Find Full Text PDF

Objectives: To conduct a comprehensive review of the literature pertaining to the broader autism phenotype, the paper endeavors to delineate the key research directions and topics, document the current research trends, and furnish insightful analyses and novel perspectives to foster future advancements in the field, with the aid of CiteSpace and VOS viewer.

Methods: CiteSpace and VOS viewer are two kinds of software for visualizing citations that is intended to examine academic literature and identify possible sources of knowledge. The Web of Science Core Collection database was used to retrieve articles from 1994 to 2024 that discussed the autism phenotype in general.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!