A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Retained Intracerebral Depth Electrode after Stereotactic Electroencephalography Monitoring: A Case Report. | LitMetric

Retained Intracerebral Depth Electrode after Stereotactic Electroencephalography Monitoring: A Case Report.

NMC Case Rep J

Department of Neurosurgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Hiroshima, Japan.

Published: February 2024

Stereotactic electroencephalography (SEEG) is an increasingly popular surgical modality for localizing the epileptogenic zone. Robot-guided stereotactic electrode placement has been covered in Japan by National Health Insurance since 2020. However, several surgical devices, such as the anchor bolt (a thin, hollow, metal shaft that serves as a guide screw or fixing for each electrode), have not been approved. A 14-year-old female who underwent SEEG for intractable epilepsy and required additional surgery to remove a retained depth electrode from the skull after the SEEG monitoring was finished. She had uncontrolled focal seizures consisting of nausea and laryngeal constriction at the onset. After a comprehensive presurgical evaluation, robot-guided stereotactic electrode implantation was performed to evaluate her seizures by SEEG. Nine depth electrodes were implanted through the twist drill hole. The electrodes were sutured to her skin for fixation without anchor bolts. When we attempted to remove the electrodes after 8 days of SEEG monitoring, one of the electrodes was retained. The retained electrode was removed through an additional skin incision and a small craniectomy under general anesthesia. We confirmed narrowing of the twist drill hole pathway in the internal table of the skull due to osteogenesis, which locked the electrode. This complication might be avoided if an anchor bolt had been used. This case report prompts the approval of the anchor bolts to avoid difficulty in electrode removal. Moreover, approval of a depth electrode with a thinner diameter and more consistent hardness is needed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10918211PMC
http://dx.doi.org/10.2176/jns-nmc.2023-0242DOI Listing

Publication Analysis

Top Keywords

depth electrode
12
electrode
9
stereotactic electroencephalography
8
case report
8
robot-guided stereotactic
8
stereotactic electrode
8
anchor bolt
8
seeg monitoring
8
twist drill
8
drill hole
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!