AI Article Synopsis

  • The International Atomic Energy Agency recommends the establishment of diagnostic reference levels (DRLs) for routine CT examinations in Africa as part of a new regional project.
  • A study involving 22 centers analyzed patient dose reports from 2156 adult patients, focusing on the most common CT procedures to establish DRLs for various body parts.
  • The established DRLs for CT dose index and dose length product were found to be comparable to data from other African countries and international standards, providing a baseline for future DRLs in Africa and developing nations.

Article Abstract

The International Atomic Energy Agency, as part of the new regional project (RAF/9/059), recommend the establishment of diagnostic reference levels (DRLs) in Africa. In response to this recommendation, this project was designed to establish and utilise national DRLs of routine computed tomography (CT) examinations. These were done by estimating CT dose index and dose length product (DLP) from a minimum of 20 patient dose report of the most frequently used procedures using 75th percentile distribution of the median values. In all, 22 centres that formed 54% of all CT equipment in the country took part in this study. Additionally, a total of 2156 adult patients dose report were randomly selected, with a percentage distribution of 60, 12, 21 and 7% for head, chest, abdomen-pelvis and lumber spine, respectively. The established DRL for volume CT dose index were 60.0, 15.7, 20.5 and 23.8 mGy for head, chest, abdomen-pelvis and lumber spine, respectively. While the established DRL for DLP were 962.9, 1102.8, 1393.5 and 824.6 mGy-cm for head, chest, abdomen-pelvis, and lumber spine, respectively. These preliminary results were comparable with data from 16 other African countries, European Commission and the International Commission on Radiological Protection. Hence, this study would serve as a baseline for the establishment of a more generalised regional and national adult DRLs for Africa and other developing countries.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncae040DOI Listing

Publication Analysis

Top Keywords

head chest
12
chest abdomen-pelvis
12
abdomen-pelvis lumber
12
lumber spine
12
diagnostic reference
8
computed tomography
8
tomography examinations
8
drls africa
8
dose report
8
spine established
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!