Comprehensive domain-specific analysis and immunoglobulin G profiling of anti-factor VIII antibodies using a bead-based multiplex immunoassay.

J Thromb Haemost

Institute of Experimental Hematology and Transfusion Medicine, University Hospital Bonn, Medical Faculty, University of Bonn, Bonn, Germany; Center for Rare Diseases Bonn (ZSEB), University Clinic Bonn, Bonn, Germany. Electronic address:

Published: June 2024

Background: Antibodies against factor (F)VIII are a major complication in the treatment of patients with severe hemophilia A. The Nijmegen-Bethesda assay (NBA) is the gold standard for detection of neutralizing antibodies (inhibitors), whereas both inhibitors and nonneutralizing antibodies can be detected by immunoassays such as enzyme-linked immunosorbent assay (ELISA) and multiplex bead-based assays.

Objectives: Evaluation of an in-house Luminex bead-based assay (LumiTope) compared with a commercially available ELISA and NBA.

Methods: The LumiTope method comprised full-length and B-domain-deleted FVIII as well as 9 purified FVIII single or multidomains. The respective proteins were coupled to magnetic beads to detect domain-specific immunoglobulin (IgG; IgG) anti-FVIII antibodies in a large cohort of patients with hemophilia A with and without inhibitors.

Results: Overall, LumiTope assay had a high sensitivity (94.9%) and specificity (91.2%), particularly in patients with low-titer inhibitors compared with ELISA (sensitivity of 72.2% vs 27.7%). IgG was the most abundant IgG subclass in NBA-positive patients. NBA-positive and -negative patients showed different domain profiles. Patients with genetic variants in the heavy chain predominantly exhibited antibodies specific to this chain, while those with a light-chain variant showed a more diverse distribution of antibody specificities. Patients with an intron 22 inversion resembled those with a light-chain defect, with a majority of antibodies targeting the light chain.

Conclusion: LumiTope assay provides a sensitive and specific method for not only detection but also domain specification of anti-FVIII-antibodies. Implementation of bead-based assays could improve antibody detection, profiling, and comparability of results and complement NBA.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtha.2024.02.016DOI Listing

Publication Analysis

Top Keywords

lumitope assay
8
antibodies
7
patients
7
assay
5
comprehensive domain-specific
4
domain-specific analysis
4
analysis immunoglobulin
4
immunoglobulin profiling
4
profiling anti-factor
4
anti-factor viii
4

Similar Publications

Comprehensive domain-specific analysis and immunoglobulin G profiling of anti-factor VIII antibodies using a bead-based multiplex immunoassay.

J Thromb Haemost

June 2024

Institute of Experimental Hematology and Transfusion Medicine, University Hospital Bonn, Medical Faculty, University of Bonn, Bonn, Germany; Center for Rare Diseases Bonn (ZSEB), University Clinic Bonn, Bonn, Germany. Electronic address:

Background: Antibodies against factor (F)VIII are a major complication in the treatment of patients with severe hemophilia A. The Nijmegen-Bethesda assay (NBA) is the gold standard for detection of neutralizing antibodies (inhibitors), whereas both inhibitors and nonneutralizing antibodies can be detected by immunoassays such as enzyme-linked immunosorbent assay (ELISA) and multiplex bead-based assays.

Objectives: Evaluation of an in-house Luminex bead-based assay (LumiTope) compared with a commercially available ELISA and NBA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!