The Moons And Jupiter Imaging Spectrometer (MAJIS) is the visible and near-infrared imaging spectrometer onboard the European Space Agency (ESA)'s Jupiter Icy Moons Explorer mission. Before its integration into the spacecraft, the instrument undergoes an extensive ground calibration to establish its baseline performances. This process prepares the imaging spectrometer for flight operations by characterizing the behavior of the instrument under various operative conditions and uncovering instrumental distortions that may depend on instrumental commands. Two steps of the on-ground calibration campaigns were held at the instrument level to produce the data. Additional in-flight measurements have recently been obtained after launch during the Near-Earth Commissioning Phase. In this article, we present the analyses of these datasets, focusing on the characterization of the spectral performances. First, we describe and analyze the spectral calibration datasets obtained using both monochromatic sources and polychromatic sources coupled with solid and gas samples. Then, we derive the spectral sampling and the spectral response function over the entire field of view. These spectral characteristics are quantified for various operational parameters of MAJIS, such as temperature and spectral binning. The derived on-ground performances are then compared with in-flight measurements obtained after launch and presented in the framework of the MAJIS performance requirements.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0188944DOI Listing

Publication Analysis

Top Keywords

imaging spectrometer
16
moons jupiter
8
jupiter imaging
8
spectral calibration
8
in-flight measurements
8
measurements launch
8
spectral
7
calibration
5
calibration majis
4
majis moons
4

Similar Publications

Microscopic mapping of infrared modulated photoluminescence spectra with a spatial resolution of ∼2 μm.

Rev Sci Instrum

December 2024

State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, 200083 Shanghai, China.

Infrared photoluminescence (PL) spectroscopy with micron-scale spatial resolution is essential for the optoelectronic characterization of narrow-gap microstructures and single defects, yet it poses significant challenges due to the exceedingly weak PL signal and strong background thermal emission. This work introduces an infrared micro-PL (μPL) mapping system that achieves a spatial resolution of ∼2 μm, leveraging the inherent advantages of the step-scan Fourier transform infrared spectrometer-based modulated PL technique in the mid- and far-infrared regions. The configuration of the experimental system is described, and a theoretical upper limit of spatial resolution is derived to be about 1.

View Article and Find Full Text PDF

Comparative analysis of clinico-metabolic profiles between St Thomas and del Nido cardioplegia solutions: A pilot study.

Perfusion

December 2024

Department of Advanced Spectroscopy and Imaging, Centre of Biomedical Research, Lucknow, India and Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India.

Introduction: Cardioplegia (CP) is integral to myocardial protection during cardiac surgery. Two standard cardioplegic solutions viz. Del Nido solution (DNS) and St Thomas solution (STS) are widely used in cardiac surgeries.

View Article and Find Full Text PDF

Ambient mass spectrometry imaging (MSI) enables hundreds of analytes in tissue sections to be directly mapped at atmospheric pressure with minimal sample preparation. This field is currently experiencing rapid growth, with numerous reported ambient ionization techniques resulting in a "hundred flowers bloom" situation. Nanospray desorption electrospray ionization (nano-DESI), developed by the Laskin group in 2010, is a widely used liquid-extraction-based ambient ionization technique that was first used for mass spectrometry imaging of tissue in 2012.

View Article and Find Full Text PDF

We report a hyperspectral Raman imaging lidar system that can remotely detect and identify typical plastic species. The system is based on a frequency-doubled, Q-switched Nd:YAG laser operating at 532 nm and an imaging spectrograph equipped with a gated intensified CCD spectrometer. Stand-off detection of plastics is achieved at 6 m away with a relatively wide field of view of 1 × 150 mm, thus providing the groundwork for better solutions in monitoring marine plastic pollution.

View Article and Find Full Text PDF

Spatial omics methods are extensions of traditional histological methods that can illuminate important biomedical mechanisms of physiology and disease by examining the distribution of biomolecules, including nucleic acids, proteins, lipids, and metabolites, at microscale resolution within tissues or individual cells. Since, for some applications, the desired resolution for spatial omics approaches the nanometer scale, classical tools have inherent limitations when applied to spatial omics analyses, and they can measure only a limited number of targets. Nanotechnology applications have been instrumental in overcoming these bottlenecks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!