A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of continuous 24-hour and 14-day ECG monitoring for the detection of cardiac arrhythmias in patients with ischemic stroke or syncope. | LitMetric

Background: Previous studies show that using 12-lead electrocardiogram (ECG) or 24-h ECG monitor for the detection of cardiac arrhythmia events in patients with stroke or syncope is ineffective.

Hypothesis: The 14-day continuous ECG patch has higher detection rates of arrhythmias compared with conventional 24-h ECG monitoring in patients with ischemic stroke or syncope.

Methods: This cross-sectional study of patients with newly diagnosed ischemic stroke or syncope received a 24-h ECG monitoring and 14-day continuous cardiac monitoring patch and the arrhythmia events were measured.

Results: This study enrolled 83 patients with ischemic stroke or syncope. The detection rate of composite cardiac arrhythmias was significantly higher for the 14-day ECG patch than 24-h Holter monitor (69.9% vs. 21.7%, p = .006). In patients with ischemic stroke, the detection rates of cardiac arrhythmias were 63.4% for supraventricular tachycardia (SVT), 7% for ventricular tachycardia (VT), 5.6% for atrial fibrillation (AF), 4.2% for atrioventricular block (AVB), and 1.4% for pause by 14-day ECG patch, respectively. The significant difference in arrhythmic detection rates were found for SVT (45.8%), AF (6%), pause (1.2%), AVB (2.4%), and VT (9.6%) by 14-day ECG patch but not by 24-h Holter monitor in patients with ischemic stroke or syncope.

Conclusions: A 14-day ECG patch can be used on patients with ischemic stroke or syncope for the early detection of AF or other cardiac arrhythmia events. The patch can be helpful for physicians in planning medical or mechanical interventions of patients with ischemic stroke and occult AF.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10918718PMC
http://dx.doi.org/10.1002/clc.24247DOI Listing

Publication Analysis

Top Keywords

ischemic stroke
32
patients ischemic
28
14-day ecg
20
stroke syncope
20
ecg patch
20
ecg monitoring
12
detection cardiac
12
cardiac arrhythmias
12
24-h ecg
12
arrhythmia events
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!