Aim: This study aims to evaluate the accuracy associated with the use of a dynamic navigation system for the lateral window opening for a direct sinus floor elevation (SFE) procedure with simultaneous implant placement.

Materials And Methods: A female patient, aged 27 years, reported to the Department of Implantology seeking treatment for her lost tooth. On radiographic examination, the residual alveolar ridge height was 6 mm in the 26 (left upper first molar) region. For the implant placement, the case was planned to be carried out under dynamic navigation (Navident, Claronav, Canada). To make the lateral window accessible to the sinus floor, an implant trajectory resembling the required window dimensions and prosthetic implant position was planned. Post-surgery cone beam computed tomography (CBCT) was taken to assess the accuracy of the lateral window and implant trajectories using Evalunav (Navident, Claronav, Canada) analysis with dynamic navigation software.

Results: There was improved accuracy of the lateral window opening, and the visualization of the lateral window was maintained in real-time throughout the procedure, which was advantageous to eliminate the tearing of the thin sinus membrane. The deviations found in the trajectory of the lateral window in comparison between the planning and post-procedure were: (a) entry was deviated by 2.83 mm; (b) the apex was deviated by 2.52 mm; (c) vertically, the apex was deviated by 0.29 mm; and (d) there was an 8.93° deviation in the angulation of the trajectory. The implant that was placed simultaneously with the SFE's accuracy was in comparison with the position that was planned: (a) entry was deviated by 0.03 mm, (b) the apex was deviated by 0.82 mm, (c) vertically, the apex was deviated by 0.82 mm, and (d) there was a 0° deviation in the angulation of the trajectory.

Conclusion: Dynamic navigation technology can help overcome complications associated with direct sinus lift procedures by providing highly accurate and precise planning and execution of the surgical procedure. This can lead to improved implant stability and a reduced risk of complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10916739PMC
http://dx.doi.org/10.7759/cureus.53621DOI Listing

Publication Analysis

Top Keywords

lateral window
24
dynamic navigation
20
apex deviated
16
direct sinus
12
sinus lift
8
implant
8
simultaneous implant
8
implant placement
8
placement case
8
window opening
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!