Objective: To report preliminary results of MP-TSCP in canine patients with glaucoma while evaluating sweep velocity, treatment efficacy, and safety utilizing standardized surgical parameters.
Animal Studied: Client-owned dogs that underwent MP-TSCP at a veterinary referral hospital.
Procedure: Medical records of 19 eyes (14 dogs) treated with MP-TSCP were reviewed. Eleven eyes were treated with a 10 s/sweep (s) velocity and 8 eyes with a 20 s/s. Laser duty cycle was set at 31.3%, mean laser energy was 2766 mW, and mean duration was 120 s per hemisphere. Minimum post-operative follow-up was 6 months. Outcomes of intraocular pressure (IOP), vision status, degree of antiglaucoma medications, and complications were evaluated.
Results: There was a significantly lower median (IQR) IOP (<25 mmHg) at each timepoint postoperatively compared to IOP pre-operatively (p < 0.05). The overall success rate for IOP control at 6 months was 84%, 100% for the 10 s/s and 62.5% for the 20 s/s. Vision was preserved in 10/11 (90%) eyes from the 10 s/s group and 4/8 (50%) eyes from the 20 s/s group at 6 months. Average number of glaucoma medications in the 10 s/s group decreased from 4.4 to 1.5 and from 3.3 to 2.5 in the 20 s/s group. Post-operative complications were mild and resolved within 1 week.
Conclusions: MP-TSCP is a non-invasive treatment alternative for canine glaucoma. Employing higher energy levels rendered long-term IOP control while retaining a high safety profile with minimal postoperative complications. There was no statistical difference between a 10 s/s and 20 s/s surgical velocity, both leading to successful surgical outcomes up to 6 months post-operatively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/vop.13208 | DOI Listing |
Med Phys
January 2025
Institute for Medical Engineering, Otto von Guericke University Magdeburg, Magdeburg, Germany.
Background: The success of embolization, a minimally invasive treatment of liver cancer, could be evaluated in the operational room with cone-beam CT by acquiring a dynamic perfusion scan to inspect the contrast agent flow.
Purpose: The reconstruction algorithm must address the issues of low temporal sampling and higher noise levels inherent in cone-beam CT systems, compared to conventional CT.
Methods: Therefore, a model-based perfusion reconstruction based on the time separation technique (TST) was applied.
Dent J (Basel)
January 2025
Discipline of Periodontics, Faculdade de Odontologia de Bauru, Universidade de São Paulo, São Paulo 05508-220, Brazil.
Individuals with Down syndrome (DS) often present with severe periodontal disease at a young age. Adjuvant treatments to scaling and root planing (SRP), such as antimicrobial photodynamic therapy (aPDT), may benefit this population. This study evaluated the effectiveness of aPDT as an adjunct to SRP in individuals with DS.
View Article and Find Full Text PDFUltrasonics
January 2025
State Key Laboratory of Intelligent Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China.
Steel precision matching parts are widely used in aerospace and automobiles. In order to ensure the stability of the system, the matching parts' mating surfaces, such as inner holes and outer shafts, are required to achieve nano-surface roughness and submicron-shape accuracy. Diamond-cutting technology is generally used for ultra-precision machining processes.
View Article and Find Full Text PDFMol Biol Evol
January 2025
Ecology, Evolution, and Behavior, 140 Gortner Lab, 1479 Gortner Ave, University of Minnesota, Saint Paul, MN 55108, USA.
Loss-of-function alleles are a pertinent source of genetic variation with the potential to contribute to adaptation. Cave-adapted organisms exhibit striking loss of ancestral traits such as eyes and pigment, suggesting that loss-of-function alleles may play an outsized role in these systems. Here, we leverage 141 whole genome sequences to evaluate the evolutionary history and adaptive potential of single nucleotide premature termination codons (PTCs) in Mexican tetra.
View Article and Find Full Text PDFAbdom Radiol (NY)
January 2025
University of Calgary, Calgary, Canada.
Objectives: Contrast enhanced ultrasound (CEUS) now joins the ranks of CT and MRI for noninvasive diagnosis of hepatocellular carcinoma (HCC). CEUS LI-RADS provides greater than 95% specificity for diagnosis within LR-5. Unlike CT/MRI, CEUS is nodule based.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!