The miniaturization of microfluidic systems usually comes at the cost of more difficult integration of sensors and actuators inside the channel. As an alternative, this work demonstrates the embedding of semiconductor-based sensor and actuator technologies that can be spatially and temporally controlled from outside the channel using light. The first element is a light-addressable potentiometric sensor, consisting of an Al/Si/SiO/SiN structure, that can measure pH changes at the SiN/electrolyte interface. The pH value is a crucial factor in biological and chemical systems, and besides measuring, it is often important to bring the system out of equilibrium or to adjust and control precisely the surrounding medium. This can be done photoelectrocatalytically by utilizing light-addressable electrodes. These consist of a glass/SnO:F/TiO structure, whereby direct charge transfer between the TiO and the electrolyte leads to a pH change upon irradiation. To complement the advantages of both, we integrated a light-addressable sensor with a pH sensitivity of 41.5 mV·pH and a light-addressable electrode into a microfluidic setup. Here, we demonstrated a simultaneous operation with the ability to generate and record pH gradients inside a channel under static and dynamic flow conditions. The results show that dependent on the light-addressable electrode (LAE)-illumination conditions, pH changes up to ΔpH of 2.75 and of 3.52 under static and dynamic conditions, respectively, were spatially monitored by the light-addressable potentiometric sensor. After flushing with fresh buffer solution, the pH returned to its initial value. Depending on the LAE illumination, pH gradients with a maximum pH change of ΔpH of 1.42 were tailored perpendicular to the flow direction. In a final experiment, synchronous LAE illumination led to a stepwise increase in the pH inside the channel.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.3c02712DOI Listing

Publication Analysis

Top Keywords

inside channel
12
light-addressable potentiometric
8
potentiometric sensor
8
light-addressable electrode
8
static dynamic
8
lae illumination
8
light-addressable
7
actively driven
4
driven light-addressable
4
light-addressable sensor/actuator
4

Similar Publications

Graphene is a single-layered sp-hybridized carbon allotrope, which is impermeable to all atomic entities other than hydrogen. The introduction of defects allows selective gas permeation; efforts have been made to control the size of these defects for higher selectivity. Permeation of entities other than gases, such as ions, is of fundamental scientific interest because of its potential application in desalination, detection and purification.

View Article and Find Full Text PDF

The ZSM-5 zeolite is the key active component in high-severity fluid catalytic cracking (FCC) catalysts and is routinely activated by phosphorus compounds in industrial production. To date, however, the detailed structure and function of the introduced phosphorus still remain ambiguous, which hampers the rational design of highly efficient catalysts. In this work, using advanced solid-state NMR techniques, we have quantitatively identified a total of seven types of P-containing complexes in P-modified ZSM-5 zeolite and clearly revealed their structure, location, and catalytic role.

View Article and Find Full Text PDF

The integration of barcode technology with smartphones on paper-based analytical devices (PADs) presents a promising approach to bridging manual detection with digital interpretation and data storage. However, previous studies of 1D barcode approaches have been limited to providing only a "yes/no" response for analyte detection. Herein, a method of using barcode readout for semiquantitative signal detection on PADs has been achieved through the integration of barcode technology with a distance-based measurement concept on PADs.

View Article and Find Full Text PDF

Skin-Inspired and Self-Powered Piezoionic Sensors for Smart Wearable Applications.

Small

January 2025

College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, Jiangsu, 215123, China.

Bio-inspired by tactile function of human skin, piezoionic skin sensors recognize strain and stress through converting mechanical stimulus into electrical signals based on ion transfer. However, ion transfer inside sensors is significantly restricted by the lack of hierarchical structure of electrode materials, and then impedes practical application. Here, a durable nanocomposite electrode is developed based on carbon nanotubes and graphene, and integrated into piezoionic sensors for smart wearable applications, such as facial expression and exercise posture recognitions.

View Article and Find Full Text PDF

Surface plasmon resonance (SPR) is normally used to measure the kinetic parameters of biomolecular interactions between a molecule immobilized on a gold surface and another one flowing in a microfluidic channel above the surface. During the SPR measurements, convection-diffusion phenomena occur inside the microfluidic channels, but they are generally minimized by appropriate experimental setup in order to obtain diffusion free kinetic parameters of the molecular interactions. In this work, for the first time, a commercial SPR apparatus has been used to obtain non canonical scientific parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?