Dual-energy computed tomography imaging with megavoltage and kilovoltage X-ray spectra.

J Med Imaging (Bellingham)

University of Chicago, Department of Radiology, Chicago, Illinois, United States.

Published: March 2024

Purpose: Single-energy computed tomography (CT) often suffers from poor contrast yet remains critical for effective radiotherapy treatment. Modern therapy systems are often equipped with both megavoltage (MV) and kilovoltage (kV) X-ray sources and thus already possess hardware for dual-energy (DE) CT. There is unexplored potential for enhanced image contrast using MV-kV DE-CT in radiotherapy contexts.

Approach: A single-line integral toy model was designed for computing basis material signal-to-noise ratio (SNR) using estimation theory. Five dose-matched spectra (3 kV, 2 MV) and three variables were considered: spectral combination, spectral dose allocation, and object material composition. The single-line model was extended to a simulated CT acquisition of an anthropomorphic phantom with and without a metal implant. Basis material sinograms were computed and synthesized into virtual monoenergetic images (VMIs). MV-kV and kV-kV VMIs were compared with single-energy images.

Results: The 80 kV-140 kV pair typically yielded the best SNRs, but for bone thicknesses , the detunedMV-80 kV pair surpassed it. Peak MV-kV SNR was achieved with dose allocated to the MV spectrum. In CT simulations of the pelvis with a steel implant, MV-kV VMIs yielded a higher contrast-to-noise ratio (CNR) than single-energy CT and kV-kV DE-CT. Without steel, the MV-kV VMIs produced higher contrast but lower CNR than single-energy CT.

Conclusions: This work analyzes MV-kV DE-CT imaging and assesses its potential advantages. The technique may be used for metal artifact correction and generation of VMIs with higher native contrast than single-energy CT. Improved denoising is generally necessary for greater CNR without metal.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10910563PMC
http://dx.doi.org/10.1117/1.JMI.11.2.023501DOI Listing

Publication Analysis

Top Keywords

computed tomography
8
megavoltage kilovoltage
8
kilovoltage x-ray
8
mv-kv de-ct
8
basis material
8
mv-kv vmis
8
cnr single-energy
8
mv-kv
6
single-energy
5
vmis
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!