A grayscale compression method to segment bone structures for 2D-3D registration of setup images in non-coplanar radiotherapy.

Biomed Phys Eng Express

Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China.

Published: March 2024

. To evaluate the performance of an automated 2D-3D bone registration algorithm incorporating a grayscale compression method for quantifying patient position errors in non-coplanar radiotherapy.. An automated 2D-3D registration incorporating a grayscale compression method to segment bone structures was proposed. Portal images containing only bone structures (Portalbone) and digitally reconstructed radiographs containing only bone structures (DRRbone) were used for registration. First, the portal image was filtered by a high-pass finite impulse response (FIR) filter. Then the grayscale range of the filtered portal image was compressed. Thresholds were determined based on the difference in gray values of bone structures in the filtered and compressed portal image to obtainPortalbone.Another threshold was applied to generateDRRbonewhen the CT image uses the ray-casting algorithm to generate DRR images. The compression performance was assessed by registering theDRRbonewith thePortalboneobtained by compressing the portal image into various grayscale ranges. The proposed registration method was quantitatively and visually validated using (1) a CT image of an anthropomorphic head phantom and its portal images obtained in different poses and (2) CT images and pre-treatment portal images of 20 patients treated with non-coplanar radiotherapy.. Mean absolute registration errors for the best compression grayscale range test were 0.642 mm, 0.574 mm, and 0.643 mm, with calculation times of 50.6 min, 42.2 min, and 49.6 min for grayscale ranges of 0-127, 0-63 and 0-31, respectively. For the accuracy validation (1), the mean absolute registration errors for couch angles 0°, 45°, 90°, 270°, and 315° were 0.694 mm, 0.839 mm, 0.726 mm, 0.833 mm, and 0.873 mm, respectively. Among the six transformation parameters, the translation error in the vertical direction contributed the most to the registration errors. Visual inspection of the patient registration results revealed success in every instance.. The implemented grayscale compression method successfully enhances and segments bone structures in portal images, allowing for accurate determination of patient setup errors in non-coplanar radiotherapy.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2057-1976/ad3050DOI Listing

Publication Analysis

Top Keywords

bone structures
24
grayscale compression
16
compression method
16
non-coplanar radiotherapy
16
portal images
16
portal image
16
registration errors
12
registration
9
grayscale
8
method segment
8

Similar Publications

Integrated transcriptomic analysis reveals evolutionary and developmental characteristics of tendon ossification in teleost.

BMC Biol

December 2024

College of Fisheries, Hubei Hongshan Laboratory/Key Lab of Freshwater Animal Breeding, Ministry of Agriculture and Rural Affairs/Engineering Research Center of Green Development for Conventional Aquatic Biological Industry in the Yangtze River Economic Belt, Ministry of Education, Huazhong Agricultural University, No. 1 Shizishan Street, Hongshan District, Wuhan, 430070, Hubei, China.

Background: Intermuscular bones (IBs) are segmental intramembranous ossifications located within myosepta. They share similarities with tendon ossification, a form of heterotopic ossification (HO). The mechanisms underlying IB formation remain incompletely understood.

View Article and Find Full Text PDF

The state-of-the-art approach to open reduction and fixation (ORIF) of zygoma fracture fragments is based on manual skills. Achieving high accuracy can be challenging. Our feasibility study on deceased body donors with artificial zygomatic fractures investigated whether virtual repositioning of the fractures and the use of customised 3D-printed titanium osteosynthesis plates was similar in accuracy to the conventional manual procedure, and whether the method was applicable in a clinical setting.

View Article and Find Full Text PDF

Introduction: Prone positioning with head rotation can influence cerebral haemodynamics, potentially affecting cerebral perfusion and oxygenation. Elderly patients with impaired brain perfusion and oxygenation are at an increased risk of developing postoperative delirium (POD). Despite this, few studies have explored whether head orientation during prone positioning contributes to POD in older adults, an aspect often overlooked by clinicians.

View Article and Find Full Text PDF

Background/aim: Gangliosides regulate bone formation and resorption. Bone formation is reduced in mice lacking ganglioside GM2/GD2 synthase due to a decrease in osteoblasts. However, the effects of the loss of complex gangliosides by the deletion of both GM2/GD2 and GD3 synthases are unknown.

View Article and Find Full Text PDF

Background/aim: This study aimed to investigate age- and sex-related morphological variations of the mandibular condyle, sigmoid notch, and coronoid process in a mid-sized German population using panoramic radiographs.

Patients And Methods: A total of 150 participants (89 males, 61 females) aged between 18 and 80 years were included. Participants were divided by age and sex.

View Article and Find Full Text PDF