Imaging static Fourier transform spectrometry (isFTS) is used for pushbroom airborne or spaceborne hyperspectral remote sensing. In isFTS, a static two-wave interferometer imprints linear interference fringes over the image of the scene, so that the spectral information is multiplexed over several instantaneous images, and numerical reconstruction is needed to recover the full spectrum for each pixel. The image registration step is crucial since insufficient accuracy leads to artefacts on the images and the estimated spectra. In order to investigate these artifacts, we performed a theoretical study and designed a simulation program. We established that registration errors create crenellated spatial patterns, the magnitude of which depends on the radiance gradient of the scene, the amplitude of the registration error, and the wavelength. In the case of sinusoidal perturbations, which may correspond for instance to mechanical vibrations of the carrier, we established that spurious peaks appear on the spectrum, similarly to what happens in dynamic FTS, but with spatial patterns specific to static interferometers.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.502337DOI Listing

Publication Analysis

Top Keywords

image registration
8
registration errors
8
imaging static
8
static fourier
8
fourier transform
8
transform spectrometry
8
spatial patterns
8
impact image
4
registration
4
errors quality
4

Similar Publications

Background And Objectives: Although previous trials have established the efficacy and safety of endovascular thrombectomy (EVT) in large ischemic core strokes, most of them excluded patients with extracranial internal carotid artery (e-ICA) occlusion. We aimed to compare outcomes in patients with e-ICA occlusion and large ischemic core infarcts treated with EVT vs medical management (MM).

Methods: This was a secondary analysis of the SELECT2 trial, a randomized controlled trial conducted at 31 international sites.

View Article and Find Full Text PDF

Importance: In the Atrial Cardiopathy and Antithrombotic Drugs in Prevention After Cryptogenic Stroke (ARCADIA) randomized clinical trial, anticoagulation did not prevent recurrent stroke among patients with a recent cryptogenic stroke and atrial cardiopathy. It is unknown whether anticoagulation prevents covert infarcts in this population.

Objective: To test the use of apixaban vs aspirin for prevention of nonlacunar covert infarcts after cryptogenic stroke in patients with atrial cardiopathy.

View Article and Find Full Text PDF

Prediction of surgical necessity in children with ureteropelvic junction obstruction using machine learning.

Ir J Med Sci

January 2025

Faculty of Medicine, Department of Pediatric Surgery Division of Pediatric Urology, Eskisehir Osmangazi University, Eskişehir, Turkey.

Background: Hydronephrosis developing at the ureteropelvic junction due to obstruction poses clinical challenges as it has the potential to cause renal damage.

Aims: This study aims to evaluate how well machine learning models such, as XGBClassifier and Logistic Regression can be used to predict the need for treatment in patients, with hydronephrosis resulting from ureteropelvic junction obstruction.

Methods: Hydronephrosis was diagnosed in the medical records of patients from January 2015 to December 2020.

View Article and Find Full Text PDF

Multiplexed Immunofluorescence (MxIF) enables detailed immune cell phenotyping, providing critical insights into cell behavior within the tumor immune microenvironment (TIME). However, signal integrity can be compromised due to the complex cyclic staining processes inherent to MxIF. Hematoxylin and Eosin (H&E) staining, on the other hand, offers complementary information through its depiction of cell morphology and texture patterns and is often visually cross-referenced with MxIF in clinical settings.

View Article and Find Full Text PDF

Purpose: We investigated the feasibility and advantages of using non-contrast CT calcium score (CTCS) images to assess pericoronary adipose tissue (PCAT) and its association with major adverse cardiovascular events (MACE). PCAT features from coronary computed tomography angiography (CCTA) have been shown to be associated with cardiovascular risk but are potentially confounded by iodine. If PCAT in CTCS images can be similarly analyzed, it would avoid this issue and enable its inclusion in formal risk assessment from readily available, low-cost CTCS images.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?