Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cjca.2024.02.026DOI Listing

Publication Analysis

Top Keywords

association prosthesis-patient
4
prosthesis-patient mismatch
4
mismatch valve
4
valve thrombosis
4
thrombosis independent
4
independent link?
4
association
1
mismatch
1
valve
1
thrombosis
1

Similar Publications

Background: Prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) is of greater concern in Asians, considering their relatively smaller annular sizes compared with Westerners. However, the prognostic significance of PPM in Asian populations has not been demonstrated.

Objectives: This study aimed to elucidate the prognostic value of PPM after TAVR in Asian patients.

View Article and Find Full Text PDF

Despite the widespread adoption of valve-in-valve transcatheter aortic valve replacement (VIV-TAVR) for patients with failed aortic bioprosthesis, the effectiveness of this treatment for Japanese patients frequently associated with small aortic annuli remains unclear. From December-2011 to October-2022, 41 consecutive patients undergoing VIV-TAVR were enrolled in this study. The endpoints were technical success, device success, early safety, and two-year mortality according to implanted surgical valve size (small valves: 19-mm and 21-mm, n = 23; large valves: 23-mm and 25-mm, n = 18).

View Article and Find Full Text PDF

Impact of Measured and Predicted Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement.

JACC Cardiovasc Interv

November 2024

University of Cologne, Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, Cologne, Germany. Electronic address:

Background: Prosthesis-patient mismatch after transcatheter aortic valve replacement (TAVR) can be measured echocardiographically (measured prosthesis-patient mismatch [PPMm]) or predicted (predicted prosthesis-patient mismatch [PPMp]) using published effective orifice area (EOA) reference values. However, the clinical implications of PPM post-TAVR remain unclear.

Objectives: This study aimed to elucidate the prevalence of PPMm and PPMp post-TAVR and their impact on mortality in a large international cohort.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is considered more effective than surgical aortic valve implantation for patients with a small aortic annulus (SAA), however, the comparative efficacy of different transcatheter heart valves (THVs) remains uncertain. A literature search was performed across databases from their inception until June 2024 to identify eligible randomized controlled trials (RCTs) and propensity-score matched (PSM) studies. Clinical outcomes were evaluated using a random-effects model to pool risk ratios (RRs) with 95 % confidence intervals (CIs).

View Article and Find Full Text PDF

Long-Term Mortality and Impact of Implantation-Associated Factors on the Incidence of Patient-Prosthesis Mismatch After Transcatheter Aortic Valve Implantation in Patients With Small Annuli.

Am J Cardiol

November 2024

Department of Cardiology, University Heart and Vascular Center Hamburg, Germany; German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Lübeck/Kiel, Germany; Department of Cardiology and Angiology, BG University Hospital Bergmannsheil, Ruhr University Bochum, Germany.

Prosthesis-patient mismatch (PPM) is a common phenomenon after transcatheter aortic valve implantation (TAVI), especially in patients with small aortic annuli. Whether factors during implantation, such as the implantation depth, have an impact on the occurrence of PPM is currently unclear. The objectives of our study were to (1) investigate the influence of procedure planning- and implantation-related factors on the occurrence of PPM and (2) evaluate the impact of PPM on long-term mortality after TAVI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?