Introduction: Aging deteriorates peripheral and central auditory structures and functions. In elders, for an accurate audiological evaluation, it is important to explore beyond the cochlear receptor. Audiograms provide an estimation of hearing thresholds, while the amplitudes and latencies of supra-threshold auditory brainstem response (ABR) can offer noninvasive measures of the auditory pathways functioning. Regarding ABR, in young populations, level-specific chirp (LS CE-chirp) stimulus has been proposed as an alternative synchronizing method to obtain larger ABR responses than those evoked by clicks. However, the supra-threshold characteristics of chirp evoked ABR, and their association to hearing thresholds is relatively unknown in the elderly. The aim of this study was to evaluate supra-threshold LS CE-chirp ABRs in an aged population by comparing their features with click ABRs, and evaluating their relationship with audiometric hearing thresholds.

Methods: We carried out a cross-sectional study to characterize the hearing of 125 adults aged over 65 years. We determined the audiometric hearing thresholds and supra-threshold ABRs elicited by LS CE-chirp and click stimuli at 80 dB nHL. We evaluated associations by means of partial correlations and covariate adjustment. We performed specific frequencies' analysis and subgroup analysis per hearing level.

Results: Wave V responses had significantly shorter latencies and larger amplitudes when elicited by LS CE-chirp as compared to click-evoked responses. Audiometric hearing thresholds correlated with age, but ABR characteristics did not. We found mild correlations between hearing thresholds and ABR characteristics, predominantly at higher frequencies and with chirp. We found scarce evidence of correlation between ABR characteristics and the average of behavioral hearing thresholds between 0.5 to 4 kHz (0.5-4 kHz PTA). After subgroup analysis according to the hearing level, no stronger or more significant correlations were found between ABR characteristics and 0.5-4 kHz PTA.

Discussion: In this study, we found that supra-threshold LS CE-chirp ABR presented some of the previously described similitudes and differences with supra-threshold click ABR in younger populations. Although, the average amplitude and latency of wave V evoked by LS CE-chirp were larger and faster than those evoked by clicks, these results should be taken with caution at the individual level, and further studies are required to state that LS CE-chirp ABRs are better than click ABRs in elders for clinical evaluations. We did not find consistent associations between hearing thresholds and supra-threshold wave V features, suggesting that these measures should be considered independently in the elderly.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000533683DOI Listing

Publication Analysis

Top Keywords

hearing thresholds
28
abr characteristics
16
supra-threshold ce-chirp
12
audiometric hearing
12
hearing
11
abr
10
supra-threshold
8
auditory brainstem
8
brainstem response
8
evoked clicks
8

Similar Publications

Efficacy analysis of intratympanic injection of dexamethasone at different concentrations for the treatment of unilateral idiopathic sudden sensorineural hearing loss.

Am J Otolaryngol

January 2025

Department of Otolaryngology-Head and Neck Surgery, Affiliated Hospital of Yangzhou University, No. 368 Hanjiang Middle Road, Yangzhou, Jiangsu Province 225001, PR China. Electronic address:

Objective: Our study tried to evaluate and compare the therapeutic efficacy of intratympanic injection of dexamethasone (DEX) at different concentrations for the treatment of idiopathic sudden sensorineural hearing loss (ISSNHL).

Methods: A prospective randomized controlled study was conducted on 203 patients with unilateral ISSNHL. Patients were divided into four groups: the control group (n = 47, systemic treatment only), the high-concentration group (n = 51, intratympanic injection of DEX 20 mg/ml), the medium-concentration group (n = 55, 10 mg/ml), and the low-concentration group (n = 50, 5 mg/ml).

View Article and Find Full Text PDF

Efficacy of Hearing Aids in Patients with Hearing Difficulties in Noise: Focus on Hidden Hearing Loss.

J Clin Med

January 2025

Assistance Publique-Hôpitaux de Paris, Hôpital Bicêtre, Service d'Oto-Rhino-Laryngologie, 78 Rue du Général Leclerc, 94270 Le Kremlin-Bicêtre, France.

Hearing aids (HAs) have been used for standard high-frequency hearing loss and tinnitus, but their effects on speech intelligibility in noise (SIN) in people with normal hearing, including hidden hearing loss (HHL), have been little explored. We included in a prospective cohort study patients who experience poor SIN and have normal pure tone average in quiet conditions or slight HL. We used open-fit HAs.

View Article and Find Full Text PDF

Purpose: Children develop social-pragmatic understanding with the help of sensory, cognitive, and linguistic functions by interacting with other people. This study aimed to explore (a) associations between auditory, demographic, cognitive, and linguistic factors and social-pragmatic understanding in children who use bilateral hearing aids (BiHAs) or bilateral cochlear implants (BiCIs) and in typically hearing (TH) children and (b) the effect of the group (BiHA, BiCI, TH) on social-pragmatic understanding when the effects of demographic, cognitive, and linguistic factors are controlled for.

Method: The Pragma test was used to assess social-pragmatic understanding in 119 six-year-old children: 25 children who use BiHAs, 29 who use BiCIs, and 65 TH children.

View Article and Find Full Text PDF

Cochlear implants are well established devices for treating severe hearing loss. However, due to the trauma caused by the insertion of the electrode and the subsequent formation of connective tissue, their clinical effectiveness varies. The aim of the current study was to achieve a long-term reduction in connective tissue growth and impedance by combining surface patterns on the electrode array with a poly-L-lactide coating containing 20% diclofenac.

View Article and Find Full Text PDF

Background: Previous studies have shown that multiple post-traumatic irradiations of the cochlea with near-infrared light (NIR) can significantly reduce noise-induced hearing loss. However, a single NIR pre-treatment was shown to have the same effect. Extending the pre-treatment time did not result in any further reduction in hearing loss.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!