A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Efficient EEG motion artifact elimination framework for ambulatory epileptic seizure detection application. | LitMetric

Efficient EEG motion artifact elimination framework for ambulatory epileptic seizure detection application.

Biomed Phys Eng Express

Department of Electronics and Communication Engineering, UCEK, JNTUK, Kakinada, 533003, Andhra Pradesh, India.

Published: March 2024

Motion artifacts are a pervasive challenge in EEG ambulatory monitoring, often obscuring critical neurological signals and impeding accurate seizure detection. In this study, we propose a new approach of outlier based grouping of two level Singular Spectrum Analysis (SSA) decomposition combined with Relative Total Variation (RTV) filter for the effective removal of motion-induced noise from ambulatory EEG data. A two-stage SSA method was employed to decompose single-channel EEG signal, which had been interfered with, into various fre quency bands. The affected sub-band signal was then subjected to an RTV filter to estimate the artifact signal. Subtracting this estimated artifact signal from the contaminated sub-band signal yielded the filtered sub-band signal. Subse quently, the filtered sub-band signal was reintegrated with the other decomposed components from noise-free bands, culminating in the generation of the ultimate denoised EEG signal. Based on the comprehensive set of simulation results, it can be deduced that the algorithm described in the paper outperforms existing methods. It demonstrates superior metrics evaluation in terms of Δ,,, andwhen compared to these alternatives. Our framework sig- nificantly enhances the quality of EEG data by successfully eliminating motion artifacts while preserving crucial brainwave information. To evaluate the prac tical impact of this noise reduction technique, we assess its performance in the context of seizure detection. The results reveal a substantial improvement in the accuracy and reliability of seizure detection algorithms when applied to EEG data preprocessed with proposed method.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2057-1976/ad2ff4DOI Listing

Publication Analysis

Top Keywords

seizure detection
16
sub-band signal
16
eeg data
12
motion artifacts
8
rtv filter
8
signal
8
eeg signal
8
artifact signal
8
filtered sub-band
8
eeg
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!