Aimed at the stability of calibration coefficients in a general non-orthogonal retrieval algorithm (NRA) of pure rotational Raman lidars (PRRLs), an orthogonal retrieval algorithm (ORA) of atmospheric temperature profiles based on the orthogonal basis function is proposed. This algorithm eliminates the correlation between the calibration coefficients in the NRA to reduce the influence of the number of calibration points and the selection scheme on the calibration coefficients. In this paper, the stabilities of calibration coefficients in the NRA and ORA are compared and analyzed, and the data analysis for atmospheric temperature profiles with a time resolution of minute-level are given, based on the developed Cloud Precipitation Potential Evaluation (CPPV) lidar data and the parallel radiosonde temperature data. The analysis results show that coefficients of variation (CVs) of ORA calibration coefficients are one order of magnitude smaller than those of NRA coefficients. The mean deviation of the ORA retrieval results is roughly reduced by 16.1% compared with the NRA, and the root-mean-square deviation is roughly reduced by 15.0% compared with the NRA. Therefore, the temperature retrieval performance of the ORA is better than that of the NRA.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.509724DOI Listing

Publication Analysis

Top Keywords

calibration coefficients
20
retrieval algorithm
12
atmospheric temperature
12
temperature profiles
12
orthogonal retrieval
8
pure rotational
8
rotational raman
8
coefficients nra
8
data analysis
8
roughly reduced
8

Similar Publications

Dental and oral health assessments in the German National Cohort (NAKO).

BMC Oral Health

January 2025

Department of Restorative Dentistry, Periodontology and Endodontology, University Medicine Greifswald, Greifswald, Germany.

Background: Despite considerable improvements in oral health in recent decades, caries and periodontitis are still widespread, ranking among the most prevalent diseases worldwide and requiring future research. The German National Cohort (NAKO Gesundheitsstudie, NAKO) is a large-scaled, multidisciplinary, nationwide, multi-centre, population-based, prospective cohort study with oral examinations that aims to provide a resource to study risk factors for major diseases. The aim of the present article is to provide the methodological background, to report on the data quality, and to present initial results of the oral examinations.

View Article and Find Full Text PDF

Objective: To develop a predictive model for microvascular invasion (MVI) in hepatocellular carcinoma (HCC) through radiomics analysis, integrating data from both enhanced computed tomography (CT) and magnetic resonance imaging (MRI).

Methods: A retrospective analysis was conducted on 93 HCC patients who underwent partial hepatectomy. The gold standard for MVI was based on the histopathological diagnosis of the tissue.

View Article and Find Full Text PDF

Quantitative fatty acid signature analysis (QFASA) is a common method of estimating the composition of prey species in the diets of consumers from polar and temperate ecosystems in which lipids are an important source of energy. A key characteristic of QFASA is that the large number of fatty acids that typically comprise lipids permits the dietary contributions of a correspondingly large number of prey types to be estimated. Several modifications to the original QFASA methods have been suggested in the literature and a significant extension of the original model published in 2017 allows simultaneous estimation of both diet proportions and calibration coefficients, which are metabolic constants in the model whose values must otherwise be estimated in independent feeding experiments.

View Article and Find Full Text PDF

Accurate quantitative assessments are crucial to understanding development of diseases and their effective treatments. Various validated perimetry and volumetry measurement methods for patients with lymphedema exist and each has its own advantages and limitations and choosing the right instrument is essential. PeriKit® (PK) is a new measurement device that requires validation.

View Article and Find Full Text PDF

Deployment of large numbers of low capital cost sensors to increase the spatial density of air quality measurements enables applications that build on mapping air at neighborhood scales. Effective deployment requires not only low capital costs for observations but also a simultaneous reduction in labor costs. The Berkeley Environmental Air Quality and CO Network (BEACON) is a sensor network measuring O, CO, NO, and NO, particulate matter (PM), and CO at dozens of locations in cities where it is deployed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!