Sound diffraction by knife-edges of finite length: Integral solution, dimensionless parameters, and explicit formulas.

J Acoust Soc Am

Department of Mechanical Engineering and Aeronautics, University of Patras, Patras, Greece.

Published: March 2024

Sound diffraction by knife-edges of finite length is considered in the frequency domain. An approximate analytical solution in integral form is derived from a previously published time domain solution. Unlike the well-established finite length diffraction solution by Svensson et al. [Acta Acust. Acust. 95(3) 568-572 (2009)], the presented solution contains no singularities and both solutions agree, except very close to the diffracting edge. It is shown that finite length diffraction can be studied based on two dimensionless parameters: one expressing the receiver's proximity to the shadow boundary and one associated with the edge length. Depending on the dimensionless parameters, a given edge can be considered a short edge, an infinitely long edge or an edge of medium length, each case with different characteristics. Furthermore, a nomograph and the corresponding database are presented. They provide the normalized diffracted field for any source/receiver location, any source frequency, and any edge length. Also, easy to compute explicit mathematical expressions are presented to approximate the analytical integral solution. These expressions, along with the database method, accelerate diffraction calculations by order of magnitude compared to the presented integral solution or the Svensson solution. Finally, predictions from all proposed methods agree reasonably well with experimental data.

Download full-text PDF

Source
http://dx.doi.org/10.1121/10.0025024DOI Listing

Publication Analysis

Top Keywords

finite length
16
integral solution
12
dimensionless parameters
12
sound diffraction
8
diffraction knife-edges
8
knife-edges finite
8
solution
8
approximate analytical
8
length diffraction
8
solution svensson
8

Similar Publications

Proximal femoral fractures are particularly common in older adults, and cases requiring conversion to total hip arthroplasty may arise because of treatment failure or osteoarthritis. Fractures around the distal screw removal holes can be problematic. This study aimed to analyze the relationship between stem length and femoral stress distribution to determine the optimal stem length.

View Article and Find Full Text PDF

Study of Thermal Effects in Fused-Tapered Pure Passive Fibers and Signal Combiners.

Nanomaterials (Basel)

January 2025

School of Physics and Optoelectronic Engineering, Beijing University of Technology, Beijing 100124, China.

This paper investigates the thermal effects in fused-tapered passive optical fibers under near-infrared absorption. The thermal effect is primarily caused by impurities, such as OH-, which absorb incident light and generate heat. Using the finite element method, the volume changes during fiber tapering were simulated, influencing power density and thermal distribution.

View Article and Find Full Text PDF

Background: Severe metaphyseal comminution and sizable bone defect of the distal femur are high risks of fixation failure. To date, no exact magnitude of comminution and bone loss is determined as an indication for augmentation of fixation construct. The present study aimed to investigate the influence of metaphyseal gap width, working length, and screw distribution on the stability of the fixation construct.

View Article and Find Full Text PDF

Introduction And Aims: Implantation of the posterior maxilla with insufficient bone height faces challenges. Studies have shown that the use of ultrashort implants can avoid additional damage. This finite element analysis study aimed to evaluate the impacts of different lengths of ultrashort implants and three surgical approaches on stress, strain, and displacement in the posterior maxilla with varying bone heights.

View Article and Find Full Text PDF

We propose a simple mathematical model to describe the mechanical relaxation of cells within a curved epithelial tissue layer represented by an arbitrary curve in two-dimensional space. This model generalises previous one-dimensional models of flat epithelia to investigate the influence of curvature for mechanical relaxation. We represent the mechanics of a cell body either by straight springs, or by curved springs that follow the curve's shape.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!