Introduction In recent times, finite element analysis (FEA) in the field of dentistry has been employed to assess the mechanical properties of biological materials and tissues, which are difficult to quantify directly within a living organism. Only a limited number of studies have examined the impact of post diameter and length on how stress is dispersed in a maxillary canine tooth. Hence, this in vitro investigation was conducted to analyze the distribution of stress in a maxillary canine tooth that was replaced using metal and fiber posts with different diameters (1.5 mm and 1.8 mm) and lengths (11 mm and 15 mm), applying FEA. Materials and methods A FEA study was performed and all models were grouped as follows: Models 1 and 5 were made of titanium (Ti) and glass fiber posts, respectively, with a diameter of 1.5 mm and a length of 15 mm with composite core and all-ceramic crown; Models 2 and 6 were made of Ti and glass fiber posts, respectively, with a diameter of 1.5 mm and a length of 11 mm with composite core and all-ceramic crown; Models 3 and 7 were made of Ti and glass fiber posts, respectively, with a diameter of 1.8 mm and a length of 15 mm with composite core and all-ceramic crown; and Models 4 and 8 were made of Ti and glass fiber posts, respectively, with a diameter of 1.8 mm and a length of 11 mm with composite core and all-ceramic crown. A force of 200 N was exerted on the ceramic crown at an angulation of 45° to the longitudinal axis of the tooth on the palatal surface above the cingulum. The failure was determined by the correlation between a larger von Mises stress estimate and an increased likelihood of failure. The resulting stresses were then contrasted with the highest possible tensile strength of the material. Results The study demonstrated that fiber posts with a diameter of 1.8 mm and an average length of 11 mm exhibited reduced stress levels in comparison to Ti posts. The largest stresses were seen at the cervical region of the tooth, regardless of the materials employed. There was no discernible alteration in stress when the length and diameter of the post were modified. The highest stress in the composite core was measured in Ti posts measuring 1.5 mm in diameter and 15 mm in length. The highest level of stress on dentin was noted in cases where a fiber post was used, as opposed to cases where a Ti post was used. The measured stress within the fiber post was insignificant. However, the pressures imparted to the dentin were greater and more uniformly distributed in comparison to the Ti post cases. Conclusion It is suggested that a composite resin core be used along with a fiber post that is larger in diameter and smaller in length, within clinical bounds, in order to lessen stress in the radicular tooth, despite the substantial coronal defect. Further clinical trials are required to assess the survival rate of these specific measurements, dimensions, and biomaterials.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10905048PMC
http://dx.doi.org/10.7759/cureus.53266DOI Listing

Publication Analysis

Top Keywords

fiber posts
28
diameter length
24
posts diameter
20
composite core
20
glass fiber
16
length composite
16
core all-ceramic
16
all-ceramic crown
16
crown models
12
models glass
12

Similar Publications

Investigate the impact of antimicrobial photodynamic therapy (aPDT) using different photosensitizers (PSs) such as indocyanine green (IG), curcumin (CC), and methylene blue (MB), with or without intracanal application of calcium hydroxide (CH), on the push-out bond strength of glass-fiber posts (GFPs) to intraradicular dentin, the chemical composition of the root substrate, and the sealing of the adhesive interface across different thirds of intraradicular dentin. A total of 112 bovine teeth underwent biomechanical preparation and were divided into eight experimental groups (n = 14 each): Negative control with deionized water; positive control with deionized water + CH; IG group with indocyanine green and infrared laser; IG + CH group; CC group with curcumin and blue LED; CC + CH group; MB group with methylene blue and red laser; and MB + CH group. The push-out bond strength was measured using a universal testing machine (n = 8), and scanning electron microscopy characterized the fracture patterns.

View Article and Find Full Text PDF

Nanophotonic inspection of deep-subwavelength integrated optoelectronic chips.

Sci Adv

January 2025

Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Institute of Photonics Technology, Jinan University, Guangzhou 510632, China.

Artificial nanostructures with ultrafine and deep-subwavelength features have emerged as a paradigm-shifting platform to advanced light-field management, becoming key building blocks for high-performance integrated optoelectronics and flat optics. However, direct optical inspection of integrated chips remains a missing metrology gap that hinders quick feedback between design and fabrications. Here, we demonstrate that photothermal nonlinear scattering microscopy can be used for direct imaging and resolving of integrated optoelectronic chips beyond the diffraction limit.

View Article and Find Full Text PDF

This study evaluated the effect of resin cements and post-space irrigation solutions on the push-out bond strength of diabetic and non-diabetic dentin. A total of 160 human central teeth (80 diabetic, 80 non-diabetic) were prepared using X5 files and obturated with AH Plus sealer and X5 gutta-percha. Post spaces were prepared, and teeth were divided into eight groups based on resin cements (Variolink N, Panavia SA Universal) and irrigation protocols (saline, saline + 2% CHX).

View Article and Find Full Text PDF

Purpose: To compare the effect of post-and-core material type and production technique on the fracture resistance of teeth.

Materials And Methods: Sixty human maxillary central incisors were used for the study. Root canal treatments were performed, and the post cavities were created.

View Article and Find Full Text PDF

Aim: To investigate the effectiveness of unconventional post space disinfection techniques, specifically Er:YAG laser, Temoporfin, and Carbon Nanoparticles (CNPs), in improving Martens hardness (MH), eliminating the smear layer (SL), and enhancing the push-out bond strength (PBS) of glass fiber posts in canal dentin.

Methods: An in vitro study was conducted utilizing 80 single-rooted extracted human teeth, which were decoronated and subjected to standardized root canal preparation. The teeth were equally distributed into four experimental groups: Group 1 (NaOCl + EDTA), Group 2 (Er: YAG laser + EDTA), Group 3 (Temoporfin + EDTA), and Group 4 (CNPs + EDTA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!