Rapid measurement of bacterial contamination in water: A catalase responsive-electrochemical sensor.

Heliyon

Environmental Biotechnology Laboratory, Department of Bioscience and Bioengineering, Indian Institute of Technology Jodhpur (IITJ), Jodhpur, 342030, Rajasthan, India.

Published: March 2024

AI Article Synopsis

Article Abstract

The present study describes the development of a potentiometric sensor for microbial monitoring in water based on catalase activity. The sensor comprises a MnO-modified electrode that responds linearly to hydrogen peroxide (HO) from 0.16 M to 3.26 M. The electrode potential drops when the HO solution is spiked with catalase or catalase-producing microorganisms that decompose HO. The sensor is responsive to different bacteria and their catalase activities. The electrochemical sensor exhibits a lower limit of detection (LOD) for at 11 CFU/ml, at 12 CFU/ml, and at 23 CFU/ml. The sensor shows high sensitivity at 3.49, 3.02, and 4.24 mV/cmdec for , , and respectively. The abiotic sensing electrode can be used multiple times without changing the response potential (up to 100 readings) with a shelf-life of over six months. The response time is a few seconds, with a total test time of 5 min. Additionally, the sensor effectively tested actual samples (drinking and grey water), which makes it a quick and reliable sensing tool. Therefore, the study offers a promising water monitoring tool with high sensitivity, stability, good detection limit, and minimum interference from other water contaminants.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10906405PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e26724DOI Listing

Publication Analysis

Top Keywords

high sensitivity
8
sensor
7
water
5
rapid measurement
4
measurement bacterial
4
bacterial contamination
4
contamination water
4
catalase
4
water catalase
4
catalase responsive-electrochemical
4

Similar Publications

Count-rate management in I SPECT/CT calibration.

EJNMMI Phys

January 2025

Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden.

Background: System calibration is essential for accurate SPECT/CT dosimetry. However, count losses due to dead time and pulse pileup may cause calibration errors, in particular for I, where high count rates may be encountered. Calibration at low count rates should also be avoided to minimise detrimental effects from e.

View Article and Find Full Text PDF

Persistent COVID-19 symptoms and associated factors in a tertiary hospital in Thailand.

J Infect Dev Ctries

December 2024

Division of Pulmonary and Critical Care Medicine, Department of Medicine, Faculty of Medicine, Thammasat University, Pathumthani 12120, Thailand.

Introduction: Coronavirus disease 2019 (COVID-19) is associated with long-term symptoms, but the spectrum of these symptoms remains unclear. We aimed to identify the prevalence and factors associated with persistent symptoms in patients at the post-COVID-19 outpatient clinic.

Methodology: This cross-sectional, observational study included hospitalized severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infected patients followed-up at a post-COVID-19 clinic between September 2021 and January 2022.

View Article and Find Full Text PDF

A Comprehensive Atlas of AAV Tropism in the Mouse.

Mol Ther

January 2025

Department of Integrative Physiology, Baylor College of Medicine, Houston, TX 77030, USA. Electronic address:

Gene therapy with Adeno-Associated Virus (AAV) vectors requires knowledge of their tropism within the body. Here we analyze the tropism of ten naturally occurring AAV serotypes (AAV3B, AAV4, AAV5, AAV6, AAV7, AAV8, AAV9, AAVrh8, AAVrh10 and AAVrh74) following systemic delivery into male and female mice. A transgene expressing ZsGreen and Cre recombinase was used to identify transduction in a cell-dependent manner based on fluorescence.

View Article and Find Full Text PDF

Purpose: Prior sperm DNA fragmentation index (DFI) thresholds for diagnosing male infertility and predicting assisted reproduction technology (ART) outcomes fluctuated between 15 and 30%, with no agreed standard. This study aimed to evaluate the impact of the sperm DFI on early embryonic development during ART treatments and establish appropriate DFI cut-off values.

Methods: Retrospectively analyzed 913 couple's ART cycles from 2021 to 2022, encompassing 1,476 IVF and 295 ICSI cycles, following strict criteria.

View Article and Find Full Text PDF

Background: The clinical manifestations and course of rheumatoid arthritis-associated interstitial lung disease (RA-ILD) exhibits considerable heterogeneity. In this study, we aimed to explore radiographic progression over a defined period, employing the Warrick score as a semi-quantitative measure in early RA-ILD, and to assess the associated risk factors for progression.

Methods: RA-ILD patients underwent consecutive Warrick scoring based on initial high-resolution computed tomography (HRCT) at diagnosis and the first follow-up.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!