Comparison of the validity and reliability of three different methods used for wrist proprioception measurement.

J Bodyw Mov Ther

Gazi University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Ankara, Turkey.

Published: January 2024

Background: ː Early detection of loss of proprioception is essential to prevent injury and maintain professional work activities. However, although many different methods are present for wrist proprioception measurement, these methods' validity and reliability studies are quite limited.

Objective: To compare the validity and reliability of the goniometer, inclinometer, and joint position sense goniometer methods used in measuring wrist active joint position sense (AJPS).

Methods: ː Thirty-two volunteer healthy participants (64 wrists) between the ages of 19-31 (mean age:23,34 ± 3,84) were included in the study. Wrist AJPS was assessed with an isokinetic dynamometer as a reference standard in addition to an inclinometer, goniometer, and joint position sense goniometer (JPSG). Spearman's Correlation Coefficient was used for validity analysis, and Intraclass Correlation Coefficient (ICC) was used to analyze test-retest reliability.

Results: ː It was found that the goniometer (p < 0.001, r = 0.529) is a moderately valid method to assess active wrist joint position sense. The JPSG (p < 0.001, r = 0.432) and inclinometer (p = 0.005, r = 0.350) have weak validity. According to the results of ICC analysis, the goniometer (p < 0.001, ICC = 0.422) and JPSG (p < 0.001, ICC = 0.369) were found to have poor reliability in assessing wrist AJPS, and the inclinometer (p = 0,183, ICC = 0,114) was not found as a reliable method.

Conclusions: ː Our results suggest that the JPSG and inclinometer should not be used in the wrist active joint position sense evaluation because of weak validity and poor reliability. The goniometer can be used in clinics and academic research to evaluate wrist joint position sense if the rater lacks a reliable and valid measurement tool.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbmt.2023.11.018DOI Listing

Publication Analysis

Top Keywords

validity reliability
12
joint position
12
position sense
12
methods wrist
8
wrist proprioception
8
proprioception measurement
8
sense goniometer
8
correlation coefficient
8
goniometer
5
comparison validity
4

Similar Publications

Mobility tasks like the Timed Up and Go test (TUG), cognitive TUG (cogTUG), and walking with turns provide insights into the impact of Parkinson's disease (PD) on motor control, balance, and cognitive function. We assess the test-retest reliability of these tasks in 262 PD participants and 50 controls by evaluating machine learning models based on wearable-sensor-derived measures and statistical metrics. This evaluation examines total duration, subtask duration, and other quantitative measures across two trials.

View Article and Find Full Text PDF

Unmanned-Aerial-Vehicle-Assisted Secure Free Space Optical Transmission in Internet of Things: Intelligent Strategy for Optimal Fairness.

Sensors (Basel)

December 2024

Qualcomm Communication Technologies (Shanghai) Co., Ltd., Shanghai 201208, China.

In this article, we consider an UAV (unmanned aerial vehicle)-assisted free space optical (FSO) secure communication network. Since FSO signal is impossible to detect by eavesdroppers without proper beam alignment and security authentication, a BS employs FSO technique to transfer information to multiple authenticated sensors, to improve the transmission security and reliability with the help of an UAV relay with decode and forward (DF) mode. All the sensors need to first send information to the UAV to obtain security authentication, and then the UAV forwards corresponding information to them.

View Article and Find Full Text PDF

(1) Background: Ultra-high dose rate (UHDR) radiation therapy needs a reliable dosimetry solution and scintillation detectors are promising candidates. In this study, we characterized an inorganic powder-based scintillation detector under a 9 MeV UHDR electron beam. (2) Methods: A mixture of ZnS:Ag powder and optic glue was coupled to an 8 m Eska GH-4001-P polymethyl methacrylate (PMMA) optical fiber.

View Article and Find Full Text PDF

A Hybrid Harmonic Curve Model for Multi-Streamer Hydrophone Positioning in Seismic Exploration.

Sensors (Basel)

December 2024

Geophysical Division of China Oilfield Services Ltd., Tianjin 300451, China.

Towed streamer positioning is a vital and essential stage in marine seismic exploration, and accurate hydrophone coordinates exert a direct and significant influence on the quality and reliability of seismic imaging. Current methods predominantly rely on analytical polynomial models for towed streamer positioning; however, these models often produce significant errors when fitting to streamers with high curvature, particularly during turning scenarios. To address this limitation, this study introduces a novel multi-streamer analytical positioning method that uses a hybrid harmonic function to model the three-dimensional coordinates of streamers.

View Article and Find Full Text PDF

Human Pose Estimation (HPE) is a computer vision application that utilizes deep learning techniques to precisely locate Key Joint Points (KJPs), enabling the accurate description of a person's pose. HPE models can be extended to facilitate Range of Motion (ROM) assessment by leveraging patient photographs. This study aims to evaluate and compare the performance of HPE models for assessing upper limbs ROM.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!