A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Simple Method for Synthesizing Nitrogen-Doped Carbon Quantum Dots for Fluorescent "Turn off" Mercury (II) Ion Sensing. | LitMetric

Here, straightforward and environmentally friendly fluorescent nitrogen doped carbon quantum dots (N-CQDs) with a high blue fluorescence emission at 455 nm are used for ultrasensitive Hg ion detection. Folic acid and urea are used as carbon sources in the carbonization process. Two broad absorption bands at around 280 and 370 nm from UV-Vis spectrum and characteristic absorption peaks from infrared spectrum confirms the successful synthesis of the N-CQDs. Energy dispersive X-Ray analysis confirmed the elemental composition of the N-CQDs. Transmission electron microscopy showed the homogeneous globular morphology of the N-CQDs with an average particle size of 65 nm. Zeta potential measurement established the stability and surface charge of N-CQDs. Dynamic light scattering measurement showed the average size of N-CQDs. With the addition of Hg ion to N-CQDs, the blue fluorescence emission is quenched. Moreover, the N-CQDs can be applied to real water sample such as pond water, river water, and tap water. The detection limit is approximately calculated to be 12 nM and linear range is 0-30 parts per billion.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10895-024-03649-1DOI Listing

Publication Analysis

Top Keywords

carbon quantum
8
quantum dots
8
n-cqds
8
blue fluorescence
8
fluorescence emission
8
simple method
4
method synthesizing
4
synthesizing nitrogen-doped
4
nitrogen-doped carbon
4
dots fluorescent
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!