Cyclosporin A (CycA) is a peptide secondary metabolite derived from fungi that plays a crucial role in transplantation surgery. Cyclic traveling wave ion mobility mass spectrometry (IM-MS) revealed an N → O peptidyl shift in singly protonated CycA to isocyclosporin A (isoA), whereas no such isomerization was observed for doubly protonated and sodiated molecules. CycA and isoA were able to be separated by considering doubly protonated precursors using a specific ion fragment. In parallel, sodium ion stabilization facilitated the simultaneous separation and quantitation of singly charged cyclosporin isomers with the limit of detection and coefficient of determination of 1.3% and 0.9908 for CycA in isoA and 1.0% and 0.9830 for isoA in CycA, respectively. Finally, H-C gHSQC NMR experiments permitted parallel recording of up to 11 cyclosporin conformers. The ratios were determined by integrating the volume of cross-peaks of the upfield resonating hydrogen in the diastereotopic methylene group of sarcosine-3.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10938282PMC
http://dx.doi.org/10.1021/acs.analchem.3c05165DOI Listing

Publication Analysis

Top Keywords

ion mobility
8
doubly protonated
8
cyca isoa
8
cyca
5
exploring effects
4
cyclosporin
4
effects cyclosporin
4
cyclosporin isocyclosporin
4
isocyclosporin rearrangement
4
ion
4

Similar Publications

Highly electroactive thiazolium [5,4-d]thiazol-2,5-dicarboxylic acid-silver electrochemiluminescent metal-organic frameworks: synthesis, properties and application in glutathione detection.

Mikrochim Acta

January 2025

Key Laboratory of Synthetic and Natural Functional Molecule Chemistry (Ministry of Education), College of Chemistry & Materials Science, Northwest University, Xi' an, 710069, PR, China.

Thiazolo[5,4-d]thiazole-2,5-dicarboxylic acid (HThz), a thiazolothiazole (TTz) derivative with carboxylic acid groups, was synthesized as a ligand for the creation of five MOFs, each associated with distinct metal ions including Ag, Mn, Co, Zn, and Cu. The cathodic electrochemiluminescence (ECL) of HThz and the resulting MOFs was investigated. HThz was found to generate ECL signals, but this process was heavily reliant on potassium persulfate (KSO) as a co-reactant.

View Article and Find Full Text PDF

Ion exchange chromatography of biotherapeutics: Fundamental principles and advanced approaches.

J Chromatogr A

January 2025

School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland. Electronic address:

Ion exchange chromatography (IEX) is an important analytical technique for the characterization of biotechnology-derived products, such as monoclonal antibodies (mAbs) and more recently, cell and gene therapy products such as messenger ribonucleic acid (mRNA) and adeno-associated viruses (AAVs). This review paper first outlines the basic principles and separation mechanisms of IEX for charge variant separation of biotherapeutics, and examines the different elution modes based on salt or pH gradients. It then highlights several recent trends when applying IEX for the characterization of biotechnology-derived products, including: i) the effective use of pH gradients, ii) the improvement of selectivity by using organic solvents in the mobile phase, multi-step gradients, or by combining ion pairing and ion exchange, and iii) the increase in analytical throughput using ultra-short columns or automated screening of conditions.

View Article and Find Full Text PDF

LFP via Nanoscale Surface Reforming with a Tiny Minimal Amount of Conductivity-Enhancing Material.

Langmuir

January 2025

Department of Mechanical Engineering, Gachon University, 1342 Seongnamdaero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Republic of Korea.

LiFePO (LFP) typically requires a conductive additive to improve its low ion and electron conductivity. In this study, we achieved significant enhancements in Li and electron mobility by applying a minimal amount of conductive material through a new coating process. The coin cell demonstrated an excellent capacity of 157.

View Article and Find Full Text PDF

We report the first implementation of ion mobility mass spectrometry combined with an ultra-high throughput sample introduction technology for high throughput screening (HTS). The system integrates differential ion mobility (DMS) with acoustic ejection mass spectrometry (AEMS), termed DAEMS, enabling the simultaneous quantitation of structural isomers that are the sub-strates and products of isomerase mediated reactions in intermediary metabolism. We demonstrate this potential by comparing DAEMS to a luminescence assay for the isoform of phosphoglycerate mutase (iPGM) distinctively present in pathogens offering an opportunity as a drug target for a variety of microbial and parasite borne diseases.

View Article and Find Full Text PDF

Due to their self-renewal and differentiation capabilities, pluripotent stem cells hold immense potential for advancing our understanding of human disease and developing cell-based or pharmacological interventions. Realizing this potential, however, requires a thorough understanding of the basal cellular mechanisms which occur during differentiation. Lipids are critical molecules that define the morphological, biochemical, and functional role of cells.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!