Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Continuous glucose monitoring (CGM) values obtained from CGM systems using the same sensor but with different internal algorithms (the first- and third-generation FreeStyle Libre (1st-gen-libre and 3rd-gen-libre, respectively)) were compared. We used 19,819 paired and simultaneously measured CGM values of 13 patients with diabetes. The average CGM value was significantly higher (P < 0.0001) and the time below range (CGM value < 70 mg/dL) was significantly lower (P < 0.0001) with the 3rd-gen-libre than with the 1st-gen-libre. There was a significant correlation (P < 0.0001) between the CGM values of the 3rd-gen-libre (y-axis, mg/dL) and 1st-gen-libre (x-axis, mg/dL) using the following formula: y = 0.9728x + 10.024. On assessing the association between glycated hemoglobin (HbA1c (%), y-axis) and the average CGM values (x-axis, mg/dL) by applying the obtained equation to previously reported 1st-gen-libre data and converting it to 3rd-gen-libre data, we obtained the equation y = 0.02628x + 3.233, indicating that the glucose management indicator reported in the West may be underestimated compared with the laboratory-measured HbA1c in the Japanese population. Glucose values from the same sensor were found to be significantly different between readers with different algorithms, and the calculation of CGM-related indices may need to be individualized for each device.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10907350 | PMC |
http://dx.doi.org/10.1038/s41598-024-55124-3 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!