We observe that the modal field distribution of a dielectric slot waveguide closely resembles a magnetic dipole antenna. Such an aperture distribution traditionally demands metals, making it ill-suited to high frequencies due to excessive ohmic loss. By terminating a dielectric slot waveguide with a matched free-space interface, a compact all-dielectric radiating magnetic dipole is realized. In this way, we introduce general-purpose dipole antennas, which have long been a mainstay of RF and microwave ranges, into the realm of light wave photonic integrated circuits. The existence of the desired magnetic dipole aperture distribution is experimentally confirmed in the terahertz range, at ∼275 GHz, and good matching is evident in the ∼-25 dB reflection level. This is the electrically smallest radiator to ever be incorporated into an all-dielectric waveguiding platform.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.516561DOI Listing

Publication Analysis

Top Keywords

magnetic dipole
16
dielectric slot
12
slot waveguide
12
aperture distribution
8
dipole
5
matched dielectric
4
waveguide all-dielectric
4
all-dielectric terahertz
4
magnetic
4
terahertz magnetic
4

Similar Publications

A fast BEM (boundary element method) based approach is developed to solve an EEG/MEG forward problem for a modern high-resolution head model. The method utilizes a charge-based BEM accelerated by the fast multipole method (BEM-FMM) with an adaptive mesh pre-refinement method (called b-refinement) close to the singular dipole source(s). No costly matrix-filling or direct solution steps typical for the standard BEM are required; the method generates on-skin voltages as well as MEG magnetic fields for high-resolution head models within 90 s after initial model assembly using a regular workstation.

View Article and Find Full Text PDF
Article Synopsis
  • This study is the first to calculate how photon-initiated pair production is affected by non-zero anomalous magnetic and electric dipole moments of leptons, considering their interplay with survival factors and potential dissociation of hadron beams.
  • The authors found that the impact of these factors is generally minor (on the percent level) in current experimental analyses but will become more significant as measurement precision improves.
  • To assist future research, the calculations have been integrated into the SuperChic Monte Carlo generator, allowing simulation of this process with adjustable parameters without additional reruns.
View Article and Find Full Text PDF

This study investigates the optical properties of carbon nanotubes (CNTs) and silicene nanotubes (SiNTs) under the influence of external magnetic fields, focusing on their linear and nonlinear optical responses. A tight-binding model is employed to analyze the effects of magnetic fields on the electronic band structure, dipole matrix elements, and various optical susceptibilities of zigzag CNTs and SiNTs. The results reveal significant magnetic field-induced modifications in both linear and nonlinear optical spectra.

View Article and Find Full Text PDF

High-Performance Circular Polarization Multiple-Resonance TADF Molecules with Enhanced Long-Range Charge Transfer Based on Chiral Paracyclophane.

J Phys Chem Lett

December 2024

State Key Laboratory of Organic Electronics and Information Displays, Institute of Advanced Materials (IAM), Nanjing University of Posts & Telecommunications, 9 Wenyuan Road, Nanjing 210023, P. R. China.

Circularly polarized multiple-resonance thermally activated delayed fluorescence (CP-MR-TADF) materials have received widespread attention in recent years, but it remains a formidable challenge to design high-performance CP-MR-TADF emitters concurrently exhibiting high quantum efficiency, narrowband emission, and high dissymmetry factor (). Here, we perform an in-depth theoretical investigation on the CP-MR-TADF materials based on [2.2] paracyclophane (pCp) derivatives.

View Article and Find Full Text PDF

Terahertz (THz) spectroscopy, an advanced label-free sensing method, offers significant potential for biomolecular detection and quantitative analysis in biological samples. Although broadband fingerprint enhancement compensates for limitations in detection capability and sensitivity, the complex optical path design in operation restricts its broader adoption. This paper proposes a multi-degree-of-freedom stretchable metasurface that supports magnetic dipole resonance to enhance the broadband THz fingerprint detection of trace analytes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!