Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: An investigation of the suitability of reagents for measuring FVIII products in a one-stage clotting assay (OSA) showed variations in their FVIII activity (FVIII:C). Most studies have focused on the activated partial thromboplastin time (APTT) reagent rather than FVIII-deficient plasma (F8DP), even though the APTT-based OSA is comprised of APTT reagents and factor-deficient plasma.
Aim: A single-centre study was conducted to clarify variations in measurements of FVIII products in an OSA using a total of 12 reagent combinations, including four APTT reagents and three types of F8DP.
Methods: FVIII:C in nine types of FVIII product-spiked plasma was measured using an OSA with four different APTT reagents and three types of F8DP.
Results: F8DP-dependent variations were found in addition to differences derived from APTT reagents. Variations in target recovery (TR) were observed for NovoEight®, Eloctate®, and Jivi®. Reduced TR for Jivi was found only for Pathromtin SL in combination with congenital F8DP (F8DP-3). This lower TR was not observed with alternative manufacturing lots of F8DP-3. The reduced TR for Jivi might be related to impaired contact activation due to lower factor XI activity in F8DP-3.
Conclusion: In addition to APTT reagents, variations in F8DPs used for OSAs can also affect FVIII:C results. F8DPs as well as the APTT reagent used for OSA should be chosen with caution, and laboratories should evaluate reagents for F8DPs as they currently do for APTT reagents, especially when lot changes occur.