Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
An electrocardiogram, used to not only assess the rate and rhythm of the heart but also to evaluate for injury to the heart, is performed by attaching 12 leads to the patient's body. A myocardial infarction can be mimicked by the misplacement of the leads. A 58-year-old man with long-distance running-associated bradycardia developed postoperative atrial fibrillation with a rapid ventricular response. He converted to normal sinus rhythm after a single oral dose of 30 milligrams of diltiazem; however, the automated reading of the electrocardiogram performed in the hospital showed new changes suggestive of a postero-lateral myocardial infarction, including Q waves in leads I and aVL, as well as early precordial R wave progression with R waves and positive T waves in V and V, and a dominant R wave (R wave to S wave ratio greater than one) in V. A cardiac work-up was entirely normal: serial troponin levels, thyroid stimulating hormone, echocardiogram, computerized tomography of the chest, and Doppler studies of the extremities. Lead misplacement during the electrocardiogram was suspected during the subsequent evaluation by an astute cardiologist; the findings were diagnostic for a left arm to right arm limb lead reversal. All the changes in myocardial infarction were absent when the electrocardiogram was repeated in the office. Misplacement of leads during an electrocardiogram is not a rare event; therefore, the clinician needs to consider the possibility of improper placement of the leads when evaluating an electrocardiogram. Indeed, emotional distress, additional diagnostic procedures, and potentially harmful procedures may be experienced by the patient from incorrect diagnoses based on electrode misplacement during an electrocardiogram; in addition, there are often increased costs to the patient and the healthcare system. Therefore, in the setting of an incorrect diagnosis attributed to lead misplacement during the performance of an electrocardiogram, the acronym MISFIT (which uses the first letters of the words "myocardial infarction simulated from improper telemetry") has been introduced. In conclusion, it is important to emphasize that a MISFIT is characterized by an electrocardiogram 'mis'diagnosis of a myocardial infarction that does not 'fit' with the clinical scenario.