A simple UHPLC-MS/MS method for determination of SET2, a selective antagonist of TRPV2 receptor, in rat plasma samples.

J Chromatogr B Analyt Technol Biomed Life Sci

Institute of Neuroimmunology, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 10 Bratislava, Slovak Republic; Department of Galenic Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Odbojarov 10, SK-832 32 Bratislava, Slovak Republic; Toxicological and Antidoping Center, Faculty of Pharmacy, Comenius University in Bratislava, Odbojarov 10, SK-832 32 Bratislava, Slovak Republic. Electronic address:

Published: March 2024

Targeting the transient receptor potential vanilloid 2 channels (TRPV2) in order to alleviate or reverse the course of several diseases including multiple cancers, cardiovascular, immunological, or neurological disorders have been a matter of focus for several years now. SET2, a selective TRPV2 inhibitor, represents an innovative molecule which came into recognition in 2019 and seems to be a promising therapeutic modality in cancer and cardiac diseases. Drug discovery and bioanalysis in clinical environment demands simple, excellent, highly reliable, fast, sensitive, and selective analytical approaches which enable unambiguous identification and quantification of demanded molecule. Here, a targeted ultra-high-performance liquid chromatography - tandem mass spectrometry with electrospray ionization was developed for the quantification of SET2 in plasma samples. The developed method enabled analysis of approx. 15 samples within one hour. Simplicity of the whole analytical procedure can be emphasized by a very simple sample pretreatment based only on the protein precipitation with organic acid (here, 2 M tricholoroacetic acid). The validation procedure was characterized by promising validation parameters and excellent sensitivity what was documented by the limit of detection value at pg.mL concentration level. Analytical validation reported intra- and interday accuracy < 15 % for all quality control samples concentration levels. Similarly, excellent level of intra- (0.1 - 4.8 %) and interday (0.5 - 3.3 %) precision for the tested quality control samples was obtained. The applicability of the developed method was proven by quantifying SET2 concentration levels in plasma samples obtained from Wistar rats that were administered this drug intraperitoneally at a dose of 25 mg/kg. We expect that our new analytical method represents a very attractive tool that could be easily implemented in pharmacokinetics studies and/or therapeutic drug monitoring. Moreover, its applicability was confirmed by the new practicability evaluation metric tool.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2024.124067DOI Listing

Publication Analysis

Top Keywords

set2 selective
8
plasma samples
8
simple uhplc-ms/ms
4
uhplc-ms/ms method
4
method determination
4
determination set2
4
selective antagonist
4
antagonist trpv2
4
trpv2 receptor
4
receptor rat
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!