Epidemiological studies of patient populations have shown that high doses of radiation increase risks of cardiovascular disease (CVD). Results from a recent meta-analysis of 93 epidemiological studies covering a wide range of doses provided evidence of a causal association between radiation exposure and CVD, and indicated excess relative risk per Gy for maximum dose below 500 mGy or delivered at low dose rates. These doses cover the range of organ doses expected from multiple diagnostic computed tomography (CT) scans. Dose-effect factors for the excess absolute risk of mortality from CVD following radiation exposure were derived from the meta-analysis. The present study uses these factors to estimate excess risks of mortality for various types of CVD, including cerebrovascular disease (CeVD), from CT scans of the body and head, assuming that the meta-analytic factors were accurate and represented a causal relationship. Estimates are based on cumulative doses to the heart and brain from CT scans performed on 105 574 patients on 12 CT scanners over a period of 5½ years. The results suggest that the excess number of deaths from CeVD could be 7 or 26 per 100 000 patients depending whether threshold brain doses of 200 mGy or 50 mGy, respectively are assumed. These results could have implications for head CT scans. However, the results rely on the validity of risk factors derived in the meta-analysis informing this assessment and which include significant uncertainties. Further incidence studies should provide better information on risk factors and dose thresholds, particularly for CeVD following head CT scans.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6498/ad2ebd | DOI Listing |
Invest Ophthalmol Vis Sci
January 2025
Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Departamento de Química Biológica Ranwel Caputto. Córdoba, Argentina.
Purpose: Stress granules (SGs) are cytoplasmic biocondensates formed in response to various cellular stressors, contributing to cell survival. Although implicated in diverse pathologies, their role in retinal degeneration (RD) remains unclear. We aimed to investigate SG formation in the retina and its induction by excessive LED light in an RD model.
View Article and Find Full Text PDFEur J Pediatr
January 2025
Pediatric Emergency Department, St. Christopher's Hospital for Children, Drexel University College of Medicine, Philadelphia, PA, USA.
Background: Computed tomography (CT) scans are widely used for evaluating children with acute atraumatic altered mental status (AMS) despite concerns about radiation exposure and limited diagnostic yield. This study aims to assess the efficacy of CT scans in this population and provide evidence-based recommendations.
Methods: A systematic review was conducted according to PRISMA guidelines.
Eur J Trauma Emerg Surg
January 2025
Department of Orthopaedics and Traumatology, University Medical Center of the Johannes Gutenberg University, 55131, Mainz, Germany.
Purpose: The absence of evidence based general guidelines for radiographic follow-ups of pediatric diaphyseal forearm fractures treated with ESIN results in an arbitrary array of X-ray examinations. In most pediatric traumatology departments, an X-ray check is carried out 4 weeks after ESIN osteosynthesis of forearm shaft fractures to detect incipient consolidation of the fracture. However, the elevated sensitivity to ionizing radiation requires special precautions in the pediatric populations.
View Article and Find Full Text PDFPediatr Radiol
January 2025
E. B. Singleton Department of Radiology, Texas Children's Hospital and Baylor College of Medicine, Houston, TX, USA.
Cardiac computed tomography angiography (CTA) is a valuable tool in the assessment of congenital and acquired cardiac disease in children. The goal of cardiac CTA is to produce images that are free of motion and provide sufficient characterization of the anatomy in question. Given the complexity of pediatric patient characteristics, including patient size, heart rate, breath-holding capability, and variant anatomy, cardiac CTA technique must be individualized to the patient as well as the indication to answer the clinical question while also minimizing radiation exposure.
View Article and Find Full Text PDFJ Acoust Soc Am
January 2025
Health Canada, Consumer and Clinical Radiation Protection Bureau, Non-Ionizing Radiation Health Sciences Division, Ottawa, Ontario K1A 1C1, Canada.
The World Health Organization Environmental Noise Guidelines provide source-based nighttime sound level (Lnight) recommendations. For non-aircraft sources, the recommended Lnight is where the absolute prevalence of high sleep disturbance (HSD) equals 3%. The Guideline Development Group did not provide an Lnight for wind turbines due to inadequate data.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!