Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The recording of epileptiform discharges from bottom-of-sulcus focal cortical dysplasia (BOSD) is often difficult during intraoperative electrocorticography (ECoG) due to the deep localization. We describe the use in this scenario of a new-generation electrode strip with high flexibility, easily adapted to cortical gyri and sulci. A right-handed 20-year-old male with drug-resistant focal epilepsy due to BOSD of the inferior frontal gyrus and daily focal aware seizures was evaluated for epilepsy surgery. Based on electroclinical and neuroimaging results, a focal cortectomy guided by ECoG was proposed. ECoG recordings were performed with new-generation cortical strips (Wise Cortical Strip; WCS®) and standard cortical strips. ECoG, performed on the convexity of the frontal cortical surface, recorded only sporadic spikes with both types of strips. Then, after microsurgical trans-sulcal dissection, WCS was molded along the sulcal surface of the suspected BOSD based on 3D-imaging reconstruction, showing continuous/subcontinuous 3-4-Hz rhythmic spike activity from the deepest electrode. Registration after resection of the BOSD did not show any epileptiform activity. Pathology showed dysmorphic neurons and gliosis. No surgical complications occurred. The patient is seizure-free after 12 months. This single case experience shows that highly flexible electrode strips with adaptability to cortical gyrations can identify IEDs originating from deep location and could therefore be useful in cases of bottom of the sulcus dysplasia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/epd2.20211 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!