Polyacrylamide hydrogels (PAH gel) and polydimethylsiloxane (PDMS, an elastomer) are two soft materials often used in cell mechanics and mechanobiology, in manufacturing lab-on-a-chip applications, among others. This is partly due to the ability to tune their elasticity with ease in addition to various chemical modifications. For affine polymeric networks, two (of three) elastic constants, Young's modulus (), the shear modulus (), and Poisson's ratio (ν), describe the purely elastic response to external forces. However, the literature addressing the experimental determination of ν for PAH (sometimes called PAA gels in the literature) and the PDMS elastomer is surprisingly limited when compared to the literature that reports values of the elastic moduli, and . Here, we present a facile method to obtain the Poisson's ratio and Young's modulus for PAH gel and PDMS elastomer based on static tensile tests. The value of ν obtained from the deformation of the sample is compared to the value determined by comparing and via a second independent method that utilizes small amplitude shear rheology. We show that the Poisson's ratio may vary significantly from the value for incompressible materials (ν = 0.5), often assumed in the literature even for soft compressible hydrogels. Surprisingly, we find a high degree of agreement between elastic constants obtained by shear rheology and macroscopic static tension test data for polyacrylamide hydrogels but not for elastomeric PDMS.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10897882 | PMC |
http://dx.doi.org/10.1021/acsapm.3c03154 | DOI Listing |
Materials (Basel)
January 2025
Institute of Process Equipment, College of Energy Engineering, Zhejiang University, Hangzhou 310007, China.
The hygrothermal aging model, based on Fick's second law of diffusion, characterizes the degradation of engineering constants in T700 carbon fiber/epoxy resin composites. It focuses on changes in the tensile modulus, shear modulus, and transverse Poisson's ratio due to moisture absorption and temperature variations. The model validates through mass change observations before and after seawater immersion, along with surface morphology assessments and tensile experiments.
View Article and Find Full Text PDFNanomaterials (Basel)
January 2025
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA.
The present work investigates the interfacial and atomic layer-dependent mechanical properties, SOC-entailing phonon band structure, and comprehensive electron-topological-elastic integration of ZrTe and NiTe. The anisotropy of Young's modulus, Poisson's ratio, and shear modulus are analyzed using density functional theory with the TB-mBJ approximation. NiTe has higher mechanical property values and greater anisotropy than ZrTe.
View Article and Find Full Text PDFData Brief
February 2025
Université Paris-Saclay, CEA, CNRS, SPEC, 91191 Gif-sur-Yvette, France.
Silicate glasses are commonly used for many important industrial applications. As such, the literature provides a wealth of different structural, physical, thermodynamic and mechanical properties for many different chemical compositions of oxide glasses. However, a frequent limitation to existing datasets is that only one or two material properties can be evaluated for a given sample.
View Article and Find Full Text PDFEur Phys J E Soft Matter
January 2025
Department of Fundamental Physics, Faculty of Physics, Alzahra University, Tehran, 1993891167, Iran.
A liquid drop resting on a soft substrate is numerically simulated as an energy minimization problem. The elastic substrate is modeled as a cubic lattice of mass-springs, to which an energy term controlling the change of volume is associated. The interfacial energy between three phases of solid, liquid, and vapor is also introduced.
View Article and Find Full Text PDFSmall Methods
January 2025
School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Flexible tactile sensors have received significant attention for use in wearable applications such as robotics, human-machine interfaces, and health monitoring. However, conventional tactile sensors face challenges in accurately measuring pressure because vertical deformation is induced by Poisson's ratio in situations where lateral strain is applied. This study shows a strain-insensitive flexible tactile sensor array without the crosstalk effect using a highly stretchable mesh.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!