Objective: Intervertebral disk (IVD) degeneration usually occurs earlier in chondrodystrophic dog breeds than in other breeds. Spinal cord compression secondary to IVD degeneration is the most common cause of myelopathy in these dogs. Standard magnetic resonance imaging (MRI) sequences permit the identification of IVD degeneration and its consequences on adjacent neurological structures. In human medicine, quantitative MRI sequences, such as magnetization transfer ratio (MTR) sequences, are developed and used to detect early IVD degeneration. This prospective randomized post-mortem comparative study aimed to evaluate the correlation between a qualitative Pfirrmann MRI grading and the MTR values of the IVD in chondrodystrophic dogs.

Materials And Methods: Vertebral columns of eight canine cadavers were frozen and thawed prior to imaging with T2-weighted and MTR sequences using a 3.0 T high-field MRI. These sequences were reviewed by two observers. A Spearman correlation coefficient was calculated in order to compare the MTR values with the Pfirrmann grade. Pearson correlation coefficients were calculated to evaluate the inter-observer agreement of the delineation of the region of interest (ROI) around the NP and the MTR values. A Wilcoxon-Mann-Whitney test was used to conclude on the significance of the correlation between the MTR values and the Pfirrmann grades.

Results: There were 138 intervertebral disks analyzed: 29/138 (21.0%) IVD were grade I, 74/138 (53.6%) grade II, and 35/138 (25.4%) grade III. No grades IV and V were present in this study. Inter-observer agreement for delineation of IVD ROI was fair ( = 0.54) but inter-observer agreement of mean MTR value within the ROI was very good ( = 0.89). Mean MTR values were 16.459% (10.0305-21.0950%) for grade I, 18.888% (10.0750-27.2400%) for grade II, and 22.813% (12.5700-31.7600%) for grade III. The mean MTR value was significantly different between each Pfirrmann grade: between grades I and II ( < 0.005), grades II and III ( < 0.05), and grades I and III ( < 0.005). There was a significant moderate positive correlation between Pfirrmann grading and mean MTR values ( = 0.516).

Conclusion: The magnetization transfer ratio seems to be an objective method to detect early intervertebral disk degeneration via quantitative analysis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10899331PMC
http://dx.doi.org/10.3389/fvets.2024.1335331DOI Listing

Publication Analysis

Top Keywords

mtr values
20
ivd degeneration
16
mri sequences
12
inter-observer agreement
12
mtr
9
magnetization transfer
8
transfer ratio
8
intervertebral disk
8
mtr sequences
8
values pfirrmann
8

Similar Publications

The complete blood count (CBC) is an important screening tool for healthy adults and a common test at periodic exams. However, results are usually interpreted relative to one-size-fits-all reference intervals, undermining the precision medicine goal to tailor care for patients on the basis of their unique characteristics. Here we study thousands of diverse patients at an academic medical centre and show that routine CBC indices fluctuate around stable values or setpoints, and setpoints are patient-specific, with the typical healthy adult's nine CBC setpoints distinguishable as a group from those of 98% of other healthy adults, and setpoint differences persist for at least 20 years.

View Article and Find Full Text PDF

Background: Research is needed to understand the impact of mental health disorders (MHD) on healthcare resource utilization (HCRU) and costs among people with human immunodeficiency virus (PWH).

Objectives: Examine the HCRU and cost burden among treatment-naïve PWH with and without MHD initiating single tablet antiretroviral regimens (STRs) and multi-tablet regimens (MTRs).

Methods: A retrospective database analysis of the US Medicaid population from Anlitiks' All Payor Claims database between 1 January 2016 and 30 June 2023 was conducted.

View Article and Find Full Text PDF

Gastric milk protein coagulation has been extensively studied using in vitro and animal models. Yet, verifying these results in humans remains essential. In this study, we assessed the feasibility of using MT MRI for monitoring milk protein coagulation in vivo in humans.

View Article and Find Full Text PDF

The minimalist optical system has a simple structure, small size, and lightweight, but the low optical complexity will produce optical aberration. Addressing the significant aberration degradation in minimalist systems, we propose a high-quality computational optical framework. This framework integrates a global point spread function (PSF) change imaging model with a transformer-based U-Net deep learning algorithm to achieve high-quality imaging in minimalist systems.

View Article and Find Full Text PDF

Purpose: To perform a systematic review about the varying definitions of "failure" of hip arthroscopy (HA) in the current literature and to provide a recommendation for the standardization of defining failure of HA.

Methods: A systematic search of electronic databases was conducted to identity Level I-IV clinical studies on HA failure published between January 2016 and July 2021 according to Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Inclusion criteria consisted of studies of patients who underwent an arthroscopic hip procedure and included a definition of failure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!