AI Article Synopsis

  • The study investigated the effectiveness of thin-section CT combined with mammography for locating clustered microcalcifications that were detected via mammograms in 69 patients.
  • Results showed that CT assisted in localizing 59% of these calcifications, and all suspicious ones identified were successfully removed during surgery.
  • Findings indicated that patients in the CT group were older, had larger clusters of microcalcifications, and that the size of these clusters was a key factor in successful CT localization.

Article Abstract

Background: To explore the capability and clinical significance of chest thin-section computed tomography (CT) for localization of mammographically detected clustered microcalcifications.

Methods: A total of 69 patients with 71 mammographically detected clustered microcalcifications received surgical biopsy under the guidance of mammography (MG), CT was used to localize calcifications combined with MG if calcifications can be seen on CT. Intraoperative mammography of the specimens were performed in all cases for identification of the resected microcalcifications. The clinical, imaging and pathological information of these patients were analyzed.

Results: A total of 42 (59.15%) cases of calcifications were localized by CT + MG, 29 (40.85%) cases were guided only by the mammography. All suspicious calcifications on the mammography were successfully removed. Pathological results showed 42 cases were cancer, 23 cases were benign, and 6 cases were atypical hyperplasia. The mean age in the CT + MG group was older than that of the MG group (54.12 vs. 49.27 years; P = 0.014). The maximum diameter of clusters of microcalcifications on mammography in the CT + MG group was larger than that of the MG group [(cranio-caudal view, 1.52 vs. 0.61 mm, P = 0.000; mediolateral oblique (MLO) view, 1.53 vs. 0.62 mm, P = 0.000)]. The gray value ratio (calcified area / paraglandular; MLO, P = 0.004) and the gray value difference (calcified area - paraglandular; MLO, P = 0.005) in the CT + MG group was higher than that of the MG group. Multivariate analysis showed that the max diameter of clusters of microcalcifications (MLO view) was a significant predictive factor of localization by CT in total patients (P = 0.001).

Conclusions: About half of the mammographically detected clustered microcalcifications could be localized by thin-section CT. Maximum diameter of clusters of microcalcifications (MLO view) was a predictor of visibility of calcifications by CT. Chest thin-section CT may be useful for localization of calcifications in some patients, especially for calcifications that are only visible in one view on the mammography.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10902948PMC
http://dx.doi.org/10.1186/s12957-024-03354-0DOI Listing

Publication Analysis

Top Keywords

mammographically detected
16
clustered microcalcifications
12
chest thin-section
12
detected clustered
12
ct + mg group
12
diameter clusters
12
clusters microcalcifications
12
mlo view
12
microcalcifications localized
8
thin-section computed
8

Similar Publications

This study evaluated the association between age at first full-term pregnancy (FFTP) and mammographic breast density (MBD) in postmenopausal women. 1,034 women, age 50-69y, were recruited from the Flemish (Belgium) population-based breast cancer screening program. Participants completed a questionnaire on lifestyle and reproductive factors.

View Article and Find Full Text PDF

Purpose: To investigate the impact of artificial intelligence (AI) reading digital mammograms in increasing the chance of detecting missed breast cancer, by studying the AI- flagged early morphology indictors, overlooked by the radiologist, and correlating them with the missed cancer pathology types.

Methods And Materials: Mammograms done in 2020-2023, presenting breast carcinomas (n = 1998), were analyzed in concordance with the prior one year's result (2019-2022) assumed negative or benign. Present mammograms reviewed for the descriptors: asymmetry, distortion, mass, and microcalcifications.

View Article and Find Full Text PDF

Objective: To identify clusters of women with similar trajectories of breast density change over four longitudinal assessments and to examine the association between these trajectories and the subsequent risk of breast cancer.

Design: Retrospective cohort study.

Setting: Data from the national breast cancer screening programme, which is embedded in the National Health Insurance Service database in Korea.

View Article and Find Full Text PDF

This study investigated the lifetime attributable risk (LAR) of radiation-induced breast cancer from mammography screening in Dubai. It aimed to explore the relationship between breast thickness, patient age, and the associated radiation dose during mammographic examinations. A retrospective analysis was conducted on 2601 patients aged 40 to 69 across five screening facilities in Dubai's healthcare system.

View Article and Find Full Text PDF

False-Negative Review from the Mammography Audit: Refining Breast Imaging Practice.

Radiographics

February 2025

From the Washington University School of Medicine, Mallinckrodt Institute of Radiology, 510 S Kingshighway Blvd, St. Louis, MO 63110.

Annual review of false-negative (FN) mammograms is a mandatory and critical component of the Mammography Quality Standards Act (MQSA) annual mammography audit. FN review can help hone reading skills and improve the ability to detect cancers at mammography. Subtle architectural distortion, asymmetries (seen only on one view), small lesions, lesions with probably benign appearance (circumscribed regular borders), isolated microcalcifications, and skin thickening are the most common mammographic findings when the malignancy is visible at retrospective review of FN mammograms.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!