Using 1/2 Descending Time in CEUS to Identify Renal Allograft Rejection.

Acad Radiol

Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Electronic address:

Published: August 2024

Rationale And Objectives: This study investigates the potential of quantitative Contrast-Enhanced Ultrasound (CEUS) parameters to distinguish between graft dysfunction due to rejection and non-rejection in kidney transplant recipients.

Methods: In this retrospective study, 50 kidney transplant patients who presented elevated serum creatinine or proteinuria were analyzed. They were categorized as rejection or non-rejection based on biopsy outcomes. These classifications were applied in both derivation (n = 33) and validation cohorts (n = 17). Prior to the biopsy, all patients underwent a CEUS. Quantitative parameters derived from the CEUS were further analyzed for their consistency and reliability. Additionally, the relationship between the Banff scores, a standard for diagnosing transplant rejections, and these CEUS parameters was explored.

Results: Significant differences between rejection and non-rejection groups were observed in the CEUS parameters of derivation cohorts. Specifically, Peak Intensity (PI), 1/2 Descending Time (DT/2), Area Under Curve (AUC), and Mean Transit Time (MTT) stood out. Sensitivity and specificity for these parameters were 76.5% and 87.5% for PI, 76.5% and 81.2% for DT/2, 76.5% and 87.5% for AUC, and 68.8% and 94.1% for MTT, respectively. DT/2 and MTT showed superior interobserver agreement compared to PI and AUC. When extrapolating the cutoff values from the derivation cohort to the validation group, DT/2 and AUC exhibited optimal diagnostic precision with positive and negative predictive values being 91.7% vs. 100% and 100% vs. 85.7%, respectively. Additionally, DT/2 effectively differentiated between mild and moderate to severe microvascular inflammation, pivotal in diagnosing antibody-mediated renal transplant rejection.

Conclusion: DT/2 from CEUS parameters presents as a reliable tool to differentiate rejection from non-rejection causes in renal transplant dysfunction. Yet, large-scale, multi-center studies are essential for further validation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2024.01.027DOI Listing

Publication Analysis

Top Keywords

ceus parameters
16
rejection non-rejection
16
1/2 descending
8
descending time
8
kidney transplant
8
765% 875%
8
renal transplant
8
ceus
7
parameters
6
dt/2
6

Similar Publications

Background : The acute effects of high-intensity interval training (HIIT) on blood pressure (BP) may depend on the exercise protocol performed. Purpose: To compare the acute effect of high and low-volume HIIT on post-exercise and ambulatory BP in untrained older females diagnosed with both type 2 diabetes (T2D) and hypertension (HTN). Methods: Fifteen females (69 [65 ─ 74] years) completed a crossover study with three experimental conditions: 1) REST (35 min in sitting position); 2) HIIT10 (10 × 1 min at 90% heart rate max [HRmax]), and 3) HIIT4 (4 × 4 min at 90% HRmax).

View Article and Find Full Text PDF

This study aimed to develop a Least Absolute Shrinkage and Selection Operator (LASSO) logistic regression (LR) model using quantitative imaging features from Shear Wave Elastography (SWE) and Contrast-Enhanced Ultrasound (CEUS) to assess the malignancy risk of BI-RADS 4 breast lesions (BLs). The features predictive of malignancy in the LASSO analysis were used to construct a nomogram. Female patients (n = 111) with BI-RADS 4 BLs detected via routine ultrasound at Ma'anshan People's Hospital underwent SWE, CEUS, and histopathological examinations were enrolled in this study.

View Article and Find Full Text PDF

Background: Contrast-enhanced ultrasound (CEUS) shows potential for the differential diagnosis of breast lesions in general, but its effectiveness remains unclear for the differential diagnosis of lesions highly suspicious for breast cancers.

Objective: This study aimed to evaluate the diagnostic value of CEUS in differentiating pathological subtypes of suspicious breast lesions defined as category 4 of US-BI-RADS.

Methods: The dataset of 150 breast lesions was prospectively collected from 150 patients who underwent routine ultrasound and CEUS examination and were highly suspected of having breast cancers.

View Article and Find Full Text PDF

Background: Prostate cancer (PCa) is the leading cause of cancer-related morbidity and mortality in men worldwide. An early and accurate diagnosis is crucial for effective treatment and prognosis. Traditional invasive procedures such as image-guided prostate biopsy often cause discomfort and complications, deterring some patients from undergoing these necessary tests.

View Article and Find Full Text PDF

Contrast-enhanced ultrasound (CEUS) is a promising modality for differentiating benign and malignant lesions in various organs, including the testis. Testicular tumors, common in young men, are often treated with radical orchiectomy, which can have significant consequences. This study aimed to analyze CEUS parameters and their association with malignant testicular tumors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!