Recent works have shown bioelectrical impedance spectroscopy (BIS) may assess tissue quality. The purpose of this project was to examine associations between ultrasound echo intensity (EI) of quadriceps muscles (vastus lateralis [VL], vastus medialis [VM], vastus intermedius [VI], rectus femoris [RF]) and BIS parameters (R0, R1, C, α, fp), and if the associations are specific to individual muscles or associated with a representation of the entire quadriceps. Twenty-two participants (age: 22 ± 4 years; BMI: 25.47 ± 3.26 kg/m) participated in all study activities. Participants had transverse ultrasound scans of each individual quadriceps muscle taken at 25, 50, and 75 % of the muscle length to generate an average EI for the VL, VM, VI, and RF, which were further averaged to generate an EI for the entire quadriceps. For BIS, participants were seated with electrodes placed on the thigh to measure the segmental quadriceps. The Cole-impedance model parameters that best fit the BIS data for each participant was used for all analyses. Pearson's correlation coefficient (r) were calculated to determine associations between muscles' EI and BIS parameters. The results suggest averaged EI of individual VL, VM, VI, RF muscles and the average EI of the segmental quadriceps were significantly related to the R0, C, α metrics of the Cole-impedance model representing quadriceps segmental tissues. This supports that segmental BIS may be an appropriate technique for rapid evaluation of segmental muscle quality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.medengphy.2024.104103 | DOI Listing |
J Strength Cond Res
January 2025
School of Sport, Recreation and Tourism Management, George Mason University, Fairfax, Virginia.
Jagim, AR, Horswill, CA, Dobbs, WC, Twohey, EE, Tinsley, GM, Fields, JB, and Jones, MT. Minimum wrestling weight for high school girls wrestling: Time to revisit minimal body fat percent. J Strength Cond Res XX(X): 000-000, 2024-The purpose of this study was to determine whether an alternative body fat percentage (BF%) could be established as a safer margin for minimal wrestling weight (MWW) determination by evaluating the distribution of BF% and MWW values naturally occurring for high school girls wrestling.
View Article and Find Full Text PDFRespir Res
January 2025
Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi'an, 710032, China.
Background: Acute pulmonary embolism represents the third most prevalent cardiovascular pathology, following coronary heart disease and hypertension. Its untreated mortality rate is as high as 20-30%, which represents a significant threat to patient survival. In view of the current lack of real-time monitoring techniques for acute pulmonary embolism, this study primarily investigates the potential of the pulsatility electrical impedance tomography (EIT) technique for the detection and real-time monitoring of acute pulmonary embolism through the collection and imaging of the pulsatile signal of pulmonary blood flow.
View Article and Find Full Text PDFBMC Nephrol
January 2025
Department of Internal Medicine, Levanger Hospital, Nord-Trøndelag Health Trust, Levanger, Norway.
Background: Accurate assessment of fluid volume and hydration status is essential in many disease states, including patients with chronic kidney disease. The aim of this study was to investigate the ability of a wearable continuous bioimpedance sensor to detect changes in fluid volume in patients undergoing regular hemodialysis (HD).
Methods: 31 patients with end-stage renal disease were enrolled and monitored with a sensor patch (Re:Balans) on the upper back through two consecutive HD sessions and the interdialytic period between.
J Neurogastroenterol Motil
January 2025
Division of Gastroenterology, Taichung Veterans General Hospital, Taichung, Taiwan.
Background/aims: Distal mean nocturnal baseline impedance (MNBI) measuring via pH-impedance may be valuable in diagnosing patients with suspected laryngopharyngeal reflux (LPR). However, its wide adoption is hindered by cost and invasiveness. This study investigates whether baseline impedance measured during high-resolution impedance manometry (HRIM-BI) can predict pathological MNBI.
View Article and Find Full Text PDFGut Liver
January 2025
Department of Internal Medicine and Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Background/aims: The incidence of steatotic liver disease (SLD) is increasing across all age groups as the incidence of obesity increases worldwide. The existing noninvasive prediction models for SLD require laboratory tests or imaging and perform poorly in the early diagnosis of infrequently screened populations such as young adults and individuals with healthcare disparities. We developed a machine learning-based point-of-care prediction model for SLD that is readily available to the broader population with the aim of facilitating early detection and timely intervention and ultimately reducing the burden of SLD.