Real-world outcomes of Omnipod DASH system use in people with type 1 diabetes: Evidence from the Association of British Clinical Diabetologists (ABCD) study.

Diabetes Res Clin Pract

Department of Diabetes and Endocrinology, University Hospitals of Derby and Burton NHS Foundation Trust, Royal Derby Hospital, Derby, UK; School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham, UK. Electronic address:

Published: March 2024

Aims: To evaluate real-world outcomes in people with Type 1 Diabetes (PwT1D) initiated on Omnipod DASH® Insulin Management System.

Methods: Anonymized clinical data were submitted to a secure web-based tool within the National Health Service network. Hemoglobin A1c (HbA1c), sensor-derived glucometrics, total daily dose of insulin (TDD), and patient-reported outcome changes between baseline and follow-up were assessed. Individuals were classified to "new-to-pump" (switched from multiple daily injections) and "established-on-pump" (switched from a tethered insulin pump) groups.

Results: 276 individuals from 11 centers [66.7 % female; 92 % White British; median age 41 years (IQR 20-50); diabetes duration 20 years (IQR 11-31); 49.3 % within "new-to-pump" group] were included. Baseline HbA1c was 8.0 ± 1.3 % (64 ± 14 mmol/mol). At follow-up [3 years (IQR 1.5-3.2)], HbA1c reduced by 0.3 % [(3 mmol/mol); p = 0.002] across the total population, 0.4 % [(5 mmol/mol); p = 0.001] in those "new-to-pump" and remained unchanged in those "established-on-pump". TDD decreased in the "new-to-pump" cohort (baseline:44.9 ± 21.0units vs follow-up:38.1 ± 15.4units, p = 0.002). Of those asked, 141/143 (98.6 %) stated Omnipod DASH had a positive impact on quality of life.

Conclusions: Omnipod DASH was associated with improvements in HbA1c in PwT1D "new-to-pump" and maintained previous HbA1c levels in those "established-on-pump". User satisfaction in all groups and TDD reduction in those "new-to-pump" were reported.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diabres.2024.111597DOI Listing

Publication Analysis

Top Keywords

omnipod dash
12
real-world outcomes
8
people type
8
type diabetes
8
"new-to-pump"
6
hba1c
5
omnipod
4
outcomes omnipod
4
dash system
4
system people
4

Similar Publications

Hybrid closed-loop (HCL) systems remain underexplored within aviation, and as atmospheric pressure changes can independently affect insulin pumps and continuous glucose monitoring readings, this preliminary study assessed the feasibility of HCL safety evaluation, in both fasting and post-prandial states, by using hypobaric chamber to simulate flights. Participants with type 1 diabetes and on HCL were studied: Medtronic Guardian 4-Medtronic 780G-SmartGuard ( = 4), Dexcom G6-Omnipod DASH-Android APS ( = 1), and Dexcom G6-Ypsomed Pump-CamAPS ( = 1). Flight cabin pressures of 550 mmHg and 750 mmHg were simulated in a hypobaric chamber.

View Article and Find Full Text PDF

Background: A tubeless, disposable insulin pump (Omnipod DASH Insulin Management System, Insulet Corporation) has demonstrated improved glycemic outcomes for people with diabetes who require insulin. The impact of the system on downstream health care events has not been studied.

Objective: To assess health care resource utilization for a Medicare population before and after starting tubeless, disposable insulin pump therapy.

View Article and Find Full Text PDF

Severe Insulin Pump-Related Adverse Events: Potential Root Causes and Impact of the COVID-19 Pandemic.

J Diabetes Sci Technol

May 2024

Office of Research and Development, VA Pittsburgh Healthcare System, Pittsburgh, PA, USA.

Objective: To explore insulin pump-associated severe adverse events (SAEs) involving intensive care unit (ICU) admissions and deaths and examine the impact of the COVID-19 pandemic on these SAEs.

Methods: Qualitative template analysis of narrative data in reported insulin pump-associated SAEs occurring between May 1, 2019, and January 31, 2021, involving MiniMed 670G, MiniMed 630G, Omnipod, Omnipod DASH, and t:slim X2 insulin pumps.

Results: Over the 21-month measurement period, 460 SAEs involving an ICU admission and 288 SAEs involving a death were reported to the Food and Drug Administration.

View Article and Find Full Text PDF

Real-world outcomes of Omnipod DASH system use in people with type 1 diabetes: Evidence from the Association of British Clinical Diabetologists (ABCD) study.

Diabetes Res Clin Pract

March 2024

Department of Diabetes and Endocrinology, University Hospitals of Derby and Burton NHS Foundation Trust, Royal Derby Hospital, Derby, UK; School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham, UK. Electronic address:

Aims: To evaluate real-world outcomes in people with Type 1 Diabetes (PwT1D) initiated on Omnipod DASH® Insulin Management System.

Methods: Anonymized clinical data were submitted to a secure web-based tool within the National Health Service network. Hemoglobin A1c (HbA1c), sensor-derived glucometrics, total daily dose of insulin (TDD), and patient-reported outcome changes between baseline and follow-up were assessed.

View Article and Find Full Text PDF

The Omnipod 5 Automated Insulin Delivery System was associated with favorable glycemic outcomes for people with type 1 diabetes (T1D) in two pivotal clinical trials. Real-world evidence is needed to explore effectiveness in nonstudy conditions. A retrospective analysis of the United States Omnipod 5 System users (aged ≥2 years) with T1D and sufficient data (≥90 days of data; ≥75% of days with ≥220 continuous glucose monitor readings/day) available in Insulet Corporation's device and person-reported datasets as of July 2023 was performed.

View Article and Find Full Text PDF