Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Since the introduction of continuous glucose monitoring (CGM) technology, developers have rigorously researched the feasibility of creating a noninvasive glucose monitoring device. In a recent pilot study, investigators reported a strong correlation between glucose values obtained from novel noninvasive monitoring device (GWave) values to venous and capillary glucose measurements. We investigated whether the level of accuracy observed in the pilot study could be reproduced in a larger cohort, using a smaller third-generation manufacturable device (Gen III GWave) containing a standardized sensor chip that can be mass produced for commercial use. The evaluation assessed concordance with capillary blood glucose, reproducibility between two Gen III devices, and accuracy during insulin-induced hypoglycemia. Assessment of samples from 75 subjects (type 2 diabetes, = 6; type 1 diabetes, = 28; nondiabetic pregnant subjects, = 10; and nondiabetic, = 31) showed that 97% of values were in Zone A with 3% in Zone B of the Clarke Error Grid, with a mean absolute relative difference of 6.7% from reference blood glucose. Comparison between two independent Gen III GWave devices demonstrated reproducibility between the sensors ( = 0.95), with 100% of values within Zone A. In the hypoglycemia assessment, measurements from the Gen III sensor tightly followed the capillary glucose measurements down to 42 mg/dL (2.3 mmol/L), whereas the CGM measurements from two different CGM only converged with the GWave and capillary glucose readings after 90 min of decreasing glucose levels. Our results show promise as potentially the first noninvasive technology. Future studies will focus on larger number of people in all glucose ranges. Real-time noninvasive blood glucose monitoring is possible using GWave technology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/dia.2024.0009 | DOI Listing |