Background: Surgeons' opinions vary on the cosmetic outcome of straight-line (SL) versus broken-line (W-plasty) closure methods. To date, no studies have compared the 2 techniques in the split-scar design model that resolves the confounding individual patient factors that affects the scar outcome.

Objective: Compare outcomes and wound cosmesis with SL versus W-plasty closure techniques.

Methods: This clinical trial was conducted with 50 linear surgical wounds randomized to SL closure on half and W-plasty on the other half. At 3 months, patients and 2 masked observers evaluated each scar using the Patient and Observer Scar Assessment Scale (Patient Observer Scar Assessment Scale [POSAS]).

Results: The mean (SD) sum of the POSAS observer component scores were 16.6 (6.18) for the SL side and 15.5 (6.37) for the W-plasty side ( p = .49). The mean (SD) sum of the POSAS patient scores were 14.4 (6.8) in SL and 15.1 (8.2) in W-plasty ( p = .59). The mean (SD) complications were 0.08 (0.06) for SL and 0.02 (0.14) for W-plasty ( p = .18).

Conclusion: No statistically significant difference in wound cosmesis or complications was noted between SL versus W-plasty closure techniques. Surgeons may want to consider whether the extra time involved in placing zigzag W-plasty lines is worthwhile.

Download full-text PDF

Source
http://dx.doi.org/10.1097/DSS.0000000000004113DOI Listing

Publication Analysis

Top Keywords

versus w-plasty
12
w-plasty closure
12
w-plasty
9
straight-line versus
8
wound cosmesis
8
patient observer
8
observer scar
8
scar assessment
8
assessment scale
8
sum posas
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!