Background: In patients with type 2 diabetes mellitus (T2DM), a decrease in muscle function may be related to changes in the biomechanical properties of skeletal muscles. However, the correlations between muscle function and the characteristics of muscle size and stiffness as measured by ultrasound in patients with T2DM are unclear. The aim of this study was to investigate the abilities of conventional ultrasound and shear wave elastography (SWE) to assess muscle properties in patients with T2DM and to correlate the findings with isokinetic muscle testing and functional tests.
Methods: Sixty patients from the Department of Endocrinology in The Third Affiliated Hospital of Southern Medical University diagnosed with T2DM were recruited in this cross-sectional study from September 2021 to September 2022. T2DM was defined based on the American Diabetes Association criteria. The exclusion criteria were a history of injury or operation of the lower limb or clinical signs of neuromuscular disorders, any muscle-induced disease, and the presence of other types of diabetes mellitus. Thirty-five matched healthy volunteers were continuously included in the control group. SWE was used to measure the muscle stiffness of the quadriceps femoris [vastus lateralis (VL), rectus femoris (RF), vastus medialis (VM), vastus intermedius (VI)] and the biceps brachii (BB) in a relaxed position, and the shear wave velocity (SWV) values were recorded. Muscle size was measured using conventional ultrasound. The participants underwent isokinetic knee extension/flexion (60°/sec) to assess muscle strength and functional tests of physical performance, including the short physical performance battery, 30-s chair stand test, timed up-and-go test, and 6-meter walk test. All demographics and measured variables were compared using the independent samples -test. Interclass correlation coefficient analysis was performed on the measurement data obtained by the two operators, and Pearson correlation coefficients were used to determine the relationships between variables.
Results: Patients with T2DM exhibited worse physical performance (P<0.05) and weaker lower limb muscle strength (P<0.05) than did healthy controls, but their handgrip strength was comparable (P=0.102). Patients with T2DM had significantly decreased muscle thickness [RF thickness: 10.69±3.21 13.09±2.41 mm, mean difference =-2.40, 95% confidence interval (CI): -3.56 to -1.24, P<0.001; anterior quadriceps thickness: 23.45±7.11 27.25±5.25 mm, mean difference =-3.80, 95% CI: -6.33 to -1.26, P=0.004] and RF cross-sectional area (3.04±1.10 4.11±0.95 cm, mean difference =-1.07, 95% CI: -1.49 to -0.64; P<0.001) compared to healthy controls. Smaller muscle size was associated with decreased muscle strength (r=0.44-0.69, all P values <0.001). Except for the BB (3.48±0.38 3.61±0.61 m/s, mean difference =-0.12, 95% CI: -0.35 to 0.11; P=0.257) and VI (2.59±0.34 2.52±0.23 m/s, mean difference =0.03, 95% CI: -0.06 to 0.18; P=0.299), the muscle stiffness in patients with T2DM was significantly decreased. For the patients with T2DM and healthy participants, the SWV of the RF was 1.66±0.23 and 1.83±0.18 m/s (mean difference =-0.17, 95% CI: -0.25 to -0.08; P<0.001), respectively; that of the VM was 1.34±0.15 and 1.51±0.16 m/s (mean difference =-0.17, 95% CI: -0.24 to -0.10; P<0.001), respectively; and that of VL was 1.38±0.19 and 1.53±0.19 m/s (mean difference =-0.15, 95% CI: -0.23 to -0.07; P<0.001), respectively. Excellent interobserver reliability of the SWV measurements on the muscle of T2DM patients was observed (all intraclass correlation coefficients >0.75; P<0.001). The SWV showed moderate correlations with muscle strength in the RF, VM, and VL (r=0.30-0.61; all P values <0.05).
Conclusions: Ultrasound technology exhibits good reliability for repeated measurements of muscle size and stiffness. Reduced muscle stiffness as detected by SWE was demonstrated in patients with diabetes and was associated with decreased muscle strength and impaired functional activity.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10895149 | PMC |
http://dx.doi.org/10.21037/qims-23-1152 | DOI Listing |
Med Phys
January 2025
Deparment of Radiation Oncology, Duke University, Durham, North Carolina, USA.
Background: Stereotactic radiosurgery (SRS) is widely used for managing brain metastases (BMs), but an adverse effect, radionecrosis, complicates post-SRS management. Differentiating radionecrosis from tumor recurrence non-invasively remains a major clinical challenge, as conventional imaging techniques often necessitate surgical biopsy for accurate diagnosis. Machine learning and deep learning models have shown potential in distinguishing radionecrosis from tumor recurrence.
View Article and Find Full Text PDFFront Radiol
January 2025
Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
Background: Dark-field chest radiography allows the assessment of the structural integrity of the alveoli by exploiting the wave properties of x-rays.
Purpose: To compare the qualitative and quantitative features of dark-field chest radiography in patients with COVID-19 pneumonia with conventional CT imaging.
Materials And Methods: In this prospective study conducted from May 2020 to December 2020, patients aged at least 18 years who underwent chest CT for clinically suspected COVID-19 infection were screened for participation.
Cureus
January 2025
Department of Breast Surgery, Japanese Red Cross Ishinomaki Hospital, Ishinomaki, JPN.
We present a case of a 46-year-old woman with recurrent breast abscess resistant to conventional treatments. Initial diagnosis of mastitis led to antibiotic therapy; however, abscess formation recurred. Subsequent interventions, including incision, drainage, and various antibiotics, were insufficient because of recurrent infections.
View Article and Find Full Text PDFJ Comput Assist Tomogr
January 2025
Department of Radiology, College of Medicine, University of Florida, Gainesville, FL.
Purpose: The purpose of this work was to evaluate the image quality of a commercial CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO).
Methods: CT number, noise, contrast-to-noise ratio (CNR), modulation transfer function (MTF), and noise power spectrum (NPS) were assessed using the ACR CT Accreditation phantom scanned with various acquisitions at 80 kV, 100 kV, 120 kV, and 135 kV, each with multiple CTDIvol values of 20 mGy, 40 mGy, and 65 mGy. Artifacts were evaluated in an anthropomorphic head phantom, a cadaver head, and in patient studies.
Photoacoustic microscopy has demonstrated outstanding performance in high-resolution functional imaging. However, in the process of photoacoustic imaging, the photoacoustic signals will be polluted by inevitable background noise. Besides, the image quality is compromised due to the biosafety limitation of the laser.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!