Evaluation of obturation techniques in primary teeth among Indians.

Bioinformation

Department of Oral Medicine and Radiology, Narsinbhai Patel Dental college and Hospital, Sankalchand Patel University, Visnagar, Gujarat, India.

Published: December 2023

Evaluation of four distinct obturating methods namely endodontic pressure syringe (n=40), reamers (n=40), Lentulo spirals driven through slow-speed handpiece (n=40) and incremental filling technique (n=4) using zinc oxide eugenol (ZOE) paste as obturating material in deciduous teeth is of interest to dentist. Hence, we are interested determining the effective obturation methodology using CBCT. Handpiece driven lentuspirals helped in optimum obturation in high percentage of root canals. Low percentage of optimally filled root canals was observed in reamers technique. Moreover, under filled root canals was low in lentuspirals technique of obturation. Thus, overfilled root canals were high in endodontic pressure syringe and reamers obturation technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10895539PMC
http://dx.doi.org/10.6026/973206300191324DOI Listing

Publication Analysis

Top Keywords

root canals
16
endodontic pressure
8
pressure syringe
8
canals low
8
filled root
8
evaluation obturation
4
obturation techniques
4
techniques primary
4
primary teeth
4
teeth indians
4

Similar Publications

Analysis of root number and canal morphology of maxillary premolars using cone-beam computed tomography.

Imaging Sci Dent

December 2024

Department of Oral and Maxillofacial Radiology, School of Dentistry, Pusan National University, Yangsan, Korea.

Purpose: This study aimed to evaluate the number of roots and type of root canals in maxillary first and second premolars within a selected Korean population utilizing cone-beam computed tomography (CBCT). Additionally, it sought to investigate potential differences in these features according to sex and tooth type.

Materials And Methods: CBCT images of 585 maxillary first premolars and 578 maxillary second premolars from 303 patients were retrospectively reviewed.

View Article and Find Full Text PDF

BACKGROUND This cone beam computed tomography (CBCT) endodontics study aimed to compare the canal-centering ability and canal transportation of Edgefile X7 and HyFlex EDM files in moderately curved mesiobuccal (MB) root canals of 30 mandibular first permanent molar teeth. MATERIAL AND METHODS Thirty permanent mandibular first molars with 10° and 24° of mesial root curvature were selected and scanned with CBCT. Two experimental groups of 15 each were made: group I: HyFlex EDM, and group II: Edgefile X7.

View Article and Find Full Text PDF

This in vitro research assessed the influence of the instrument kinematics (rotary and reciprocating) and the apical preparation limit on the root canal disinfection and apical bacterial extrusion. After 21 days of Enterococcus faecalis biofilm formation in 72 mesial root canals of mandibular molars, the root canals were distributed into 2 groups (n = 36) according to the systems used for preparation: ProDesign S and Reciproc. The groups were redistributed according to the limit of apical preparation (n = 11): (a) 1 mm up to the apical foramen (TL-1); (b) at the apical foramen (TL = 0); (c) 1 mm beyond the apical foramen (TL + 1).

View Article and Find Full Text PDF

The novel assessment to explore the cutting performance of rotary instruments using dynamic finite element analysis with failure mode.

J Endod

December 2024

Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National University Hospital, 1, Chang-de St., Taipei, 100, Taiwan; National Taiwan University Hospital, National Taiwan University, No. 1, Chang-De St., Taipei City 100, Taiwan, ROC; School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Rd., Kaohsiung City, 80708, Taiwan, ROC. Electronic address:

Introduction: The separation of nickel-titanium endodontic instruments due to excessive torque adversely affects treatment outcomes. Previous studies have analyzed torque values under static conditions and failed to accurately simulate the dynamic conditions of instruments within root canals. This study aimed to apply a novel finite element analysis (FEA) to assess the real-time dynamic performance of nickel-titanium endodontic instruments during operation in root canals.

View Article and Find Full Text PDF

Background: The working length determination is necessary before root canal shaping, chemical cleaning, disinfection, and obturation in pulpectomy of primary dentition. This study aimed to evaluate the accuracy of Wirele-X and compare it with DentaPort ZX and Woodpex III in primary molar teeth.

Methods: The in vitro study was performed by using 30 extracted primary mandibular molar teeth.

View Article and Find Full Text PDF