Advancing 3D printed microfluidics with computational methods for sweat analysis.

Mikrochim Acta

UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey.

Published: February 2024

The intricate tapestry of biomarkers, including proteins, lipids, carbohydrates, vesicles, and nucleic acids within sweat, exhibits a profound correlation with the ones in the bloodstream. The facile extraction of samples from sweat glands has recently positioned sweat sampling at the forefront of non-invasive health monitoring and diagnostics. While extant platforms for sweat analysis exist, the imperative for portability, cost-effectiveness, ease of manufacture, and expeditious turnaround underscores the necessity for parameters that transcend conventional considerations. In this regard, 3D printed microfluidic devices emerge as promising systems, offering a harmonious fusion of attributes such as multifunctional integration, flexibility, biocompatibility, a controlled closed environment, and a minimal requisite analyte volume-features that leverage their prominence in the realm of sweat analysis. However, formidable challenges, including high throughput demands, chemical interactions intrinsic to the printing materials, size constraints, and durability concerns, beset the landscape of 3D printed microfluidic devices. Within this paradigm, we expound upon the foundational aspects of 3D printed microfluidic devices and proffer a distinctive perspective by delving into the computational study of printing materials utilizing density functional theory (DFT) and molecular dynamics (MD) methodologies. This multifaceted approach serves manifold purposes: (i) understanding the complexity of microfluidic systems, (ii) facilitating comprehensive analyses, (iii) saving both cost and time, (iv) improving design optimization, and (v) augmenting resolution. In a nutshell, the allure of 3D printing lies in its capacity for affordable and expeditious production, offering seamless integration of diverse components into microfluidic devices-a testament to their inherent utility in the domain of sweat analysis. The synergistic fusion of computational assessment methodologies with materials science not only optimizes analysis and production processes, but also expedites their widespread accessibility, ensuring continuous biomarker monitoring from sweat for end-users.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10899357PMC
http://dx.doi.org/10.1007/s00604-024-06231-5DOI Listing

Publication Analysis

Top Keywords

sweat analysis
16
printed microfluidic
12
microfluidic devices
12
sweat
8
printing materials
8
analysis
5
microfluidic
5
advancing printed
4
printed microfluidics
4
microfluidics computational
4

Similar Publications

User Outcomes for an App-Delivered Hypnosis Intervention for Menopausal Hot Flashes: Retrospective Analysis.

JMIR Form Res

January 2025

Mind-Body Medicine Lab, Department of Psychology and Neuroscience, Baylor University, Waco, TX, United States.

Background: Hypnotherapy has been shown to be a safe, nonhormonal intervention effective for treating menopausal hot flashes. However, women experiencing hot flashes may face accessibility barriers to in-person hypnotherapy. To solve this issue, a smartphone app has been created to deliver hypnotherapy.

View Article and Find Full Text PDF

Microtubule-stabilizing agents (enfortumab vedotin and brentuximab vedotin) and microtubule-disrupting agents (docetaxel and paclitaxel) are used as anticancer agents but can also induce drug eruptions. Recently, mitotic arrest figures have been reported in various non-neoplastic cells as the histopathologic side effect of these drug eruptions. Therefore, we performed a comparative analysis of drug eruptions associated with these microtubule-targeting agents.

View Article and Find Full Text PDF

Introduction of Ivacaftor/Lumacaftor in Children With Cystic Fibrosis Homozygous for F508del in the Netherlands: A Nationwide Real-Life Study.

Pediatr Pulmonol

January 2025

Beatrix Children's Hospital Department of Pediatric Pulmonology and Pediatric Allergy, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.

Introduction: Lumacaftor/ivacaftor (lum/iva) was introduced in the Netherlands in 2017. We investigated 1-year efficacy of lum/iva on lung function and small airway and structural lung disease evaluated by multiple breath nitrogen washout and CT scan. Additionally, we investigated effects of lum/iva on exacerbations, anthropometry, sweat chloride and safety in children with CF in the Netherlands.

View Article and Find Full Text PDF

Using a laser-scribed (direct printing) technique, we have fabricated an enzymeless, mediatorless, and paper-interfaced electrochemical device (P-LSG) for uric acid detection on a flexible polyimide sheet. Various paper substrates were investigated, and it was found that Whatman filter paper-1 is promising to obtain the best electrochemical signals at the small volume of electrolyte, i.e.

View Article and Find Full Text PDF

Objective: To investigate the effect of hyperbaric oxygen (HBO) on paroxysmal sympathetic hyperexcitation (PSH) after brain injury.

Methods: A multicenter retrospective study was conducted. Fifty-six patients with PSH who received HBO treatment from four hospitals in Henan Province from January 2021 to September 2023 were selected as the HBO group, and 36 patients with PSH who did not receive HBO treatment from Zhengzhou People's Hospital from May 2018 to December 2020 were selected as the control group.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!