Evaluation of Corrosion Performance of AZ31 Mg Alloy in Physiological and Highly Corrosive Solutions.

ACS Appl Bio Mater

School of Pharmacy and Biomedical Sciences, Faculty of Science and Health, University of Portsmouth, St Michael's Building, White Swan Road, Portsmouth PO1 2DT, U.K.

Published: March 2024

Resorbable Mg and Mg alloys have gained significant interest as promising biomedical materials. However, corrosion of these alloys can lead to premature reduction in their mechanical properties, and therefore their corrosion rate needs to be controlled. The aim of this study is to select an appropriate environment where the effects of coatings on the corrosion rate of the underlying Mg alloy can be discerned and measured in a relatively short time period. The corrosion resistance of uncoated AZ31 alloy in different solutions [Hank's Balanced Salt Solution, 1× phosphate buffered solution (PBS), 4× PBS, 0.9%, 3.5%, and 5 M sodium chloride (NaCl)] was determined by measuring the weight loss over a 2 week period. Upon exposure to physiological solutions, the uncoated AZ31 alloys exhibited a variable weight increase of 0.4 ± 0.4%. 3.5% and 5 M NaCl solutions led to 0.27 and 9.7 mm/year corrosion rates, respectively, where the compositions of corrosion products from AZ31 in all saline solutions were similar. However, the corrosion of the AZ31 alloy when coated by electrochemical oxidation with two phosphate coatings, one containing fluorine (PF) and another containing both fluorine and silica (PFS), showed 0.3 and 0.25 mm/year corrosion rates, respectively. This is more than 30 times lower than that of the uncoated alloy (7.8 mm/year), making them promising candidates for corrosion protection in severe corrosive environments. Cross-sections of the samples showed that the coatings protected the alloy from corrosion by preventing access of saline to the alloy surface, and this was further reinforced by corrosion products from both the alloy and the coatings forming an additional barrier. The information in this paper provides a methodology for evaluating the effects of coatings on the rate of corrosion of magnesium alloys.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10952013PMC
http://dx.doi.org/10.1021/acsabm.3c01169DOI Listing

Publication Analysis

Top Keywords

az31 alloy
12
corrosion
12
alloy
8
corrosion rate
8
effects coatings
8
uncoated az31
8
mm/year corrosion
8
corrosion rates
8
corrosion products
8
az31
5

Similar Publications

The effect of the sodium silicate inhibitor on the corrosion protection of the AZ31 magnesium alloy at room temperature was investigated. The results of electrochemical measurement and weight loss experiments showed that incorporating the sodium silicate significantly enhanced the anti-corrosion property of the AZ31 alloy. When the alloy was immersed in the corrosive solution with the 0.

View Article and Find Full Text PDF

This study investigates the application of Electrochemical Micromachining (ECMM) on magnesium alloy AZ31 using a hollow tool electrode. Magnesium alloys, particularly AZ31, are valued for their lightweight properties and strength-to-weight ratio but pose challenges in precision machining due to their high reactivity and susceptibility to corrosion. Utilizing a hollow tool electrode in ECMM offers potential advantages in precision and control, crucial for micro-scale manufacturing applications.

View Article and Find Full Text PDF

Enhanced adhesion and wear resistance of DLC films on AZ31 alloy achieved with high bias voltage.

Heliyon

October 2024

School of Intelligent Manufacturing Engineering, Harbin Huade University, Harbin, 150025, Heilongjiang, China.

Article Synopsis
  • Diamond-like carbon (DLC) films were applied to AZ31 surfaces without an adhesive layer, showcasing high adhesion and excellent wear resistance.
  • Various structural analyses including SEM, TEM, and Raman spectroscopy were employed, and mechanical properties were assessed through nano-indentation and scratch tests.
  • High substrate bias (-500 to -800 V) resulted in greater compressive stress and film hardness, while moderate to low bias levels (-300 to 500 V and 0 to -300 V, respectively) exhibited diminishing mechanical properties as substrate temperature increased.
View Article and Find Full Text PDF

In this research, Cu-doped fluorohydroxyapatite (Cu-FHAp) coatings containing varying levels of Cu in electrolyte as a dopant were synthesized by the ultrasonic-assisted pulse-reverse electrodeposition method on AZ31 alloy to improve the biocompatibility and corrosion resistance of the alloy for biomedical applications. Microstructural analysis revealed that the inclusion of the Cu dopant results in the formation of a more uniform coating. Energy dispersive spectroscopy analysis highlights a notable incorporation of copper within the fluorohydroxyapatite structure.

View Article and Find Full Text PDF

Objectives: The primary objective of this study is using an anodizing intermediate layer to improve corrosion resistance and adhesion of hydroxyapatite coated AZ31 alloy for applications in biodegradable implants.

Methods: An anodizing intermediate layer was formed on the surface of AZ31 substrate at various anodizing voltage of 10, 20, 30, and 40 V respectively by anodizing process. HAp was grow on the surface of AZ31 substrate at 90°C and pH solution of 7.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!