Purpose: To address if corneal biomechanical behavior has a predictive value for the presence of glaucomatous optical neuropathy in eyes with high myopia.
Patients And Methods: This observational cross-sectional study included 209 eyes from 108 consecutive patients, divided into four groups: high myopia and primary open-angle glaucoma (POAG) - HMG, n = 53; high myopia without POAG - HMNG, n = 53; non-myopic with POAG - POAG, n = 50; non-myopic and non-POAG- NMNG, n = 53. Biomechanical assessment was made through a Scheimpflug-camera-based technology. Receiver operating characteristic curves were made for the discrimination between groups. Multivariable logistic regression models were performed to address the predictive value of corneal biomechanics for the presence of glaucoma.
Results: Areas Under the Receiver Operating Characteristic (AUROCs) above 0.6 were found in 6 parameters applied to discriminate between HMG and HMNG and six parameters to discriminate between POAG and NMNG. The biomechanical models with the highest power of prediction for the presence of glaucoma included 5 parameters with an AUROC of 0.947 for eyes with high myopia and 6 parameters with an AUROC of 0.857 for non-myopic eyes. In the final model, including all eyes, and adjusted for the presence of high myopia, the highest power of prediction for the presence of glaucoma was achieved including eight biomechanical parameters, with an AUROC of 0.917.
Conclusion: Corneal biomechanics demonstrated differences in eyes with glaucoma and mainly in myopic eyes. A biomechanical model based on multivariable logistic regression analysis and adjusted for high myopia was built, with an overall probability of 91.7% for the correct prediction of glaucomatous damage.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10895980 | PMC |
http://dx.doi.org/10.2147/OPTH.S426635 | DOI Listing |
PLoS One
January 2025
Department of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Purpose: We sought to evaluate the relationship between blood vitamin A levels and myopia in adults aged ≥20 years in Korea.
Methods: We collected data of 15,899 participants aged ≥20 years from the Korean National Health and Nutrition Examination Survey. Participants underwent refraction tests to identify myopia and high myopia, and their blood pressure and obesity levels were measured.
Int Ophthalmol
January 2025
Department of Ophthalmology, Faculty of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, 217 Hong Bang Str., Ward 11, District 5, Ho Chi Minh City, 700000, Vietnam.
Purpose: This study evaluates the effectiveness of the inverted internal limiting membrane (ILM) flap technique during vitrectomy for treating macular hole-induced retinal detachment (MHRD) in high myopia patients, a challenging complication for vitreoretinal surgeons due to its treatment complexity.
Methods: We conducted a prospective study analyzing 92 eyes diagnosed with MHRD, all undergoing vitrectomy using the inverted ILM flap technique between February 2022 and September 2024. Successful surgery was defined as achieving retinal reattachment, macular hole closure, and improvement in visual acuity by the 12-month postoperative follow-up.
Int Ophthalmol
January 2025
Department of Ophthalmology, Faculty of Medicine, Hitit University, Çorum, Turkey.
Purpose: To examine the detailed vascular and morphological characteristics of the choroidal tissue in subjects with myopia.
Methods: A total of 111 subjects with myopia were included in the study. The study was conducted in three groups according to spherical equivalent(SE).
Ann Med
December 2025
Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu City, China.
Objectives: The objective of the investigation is to examine the long term efficacy, safety, and predictability of ICL-V4c implantation for high and super-high myopic patients in order to provide reliable guidance for the selection of refractive surgical procedures.
Methods: We reviewed 125 eyes from 64 patients who implanted ICL-V4c at the Refractive Surgery Center of West China Hospital in Chengdu, China, between May 2015 and January 2017. These eyes were divided into two groups based on their preoperative spherical equivalent (SE) degree: high myopia (≥ -10D) and super-high myopia groups (< -10D).
Ophthalmology
January 2025
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou 510623, China. Electronic address:
Purpose: To describe the longitudinal changes in peripapillary retinal nerve fiber layer (pRNFL) and macular ganglion cell-inner plexiform layer (mGC-IPL) thicknesses in highly myopic eyes with and without glaucoma, and to investigate the effects of high myopia (HM) on the sectoral patterns of pRNFL and mGC-IPL thinning.
Design: Longitudinal cohort study.
Participants: A total of 243 eyes from 243 individuals with 3-year follow-up were included in this study: 109 eyes in the HM group, 64 eyes in the open-angle glaucoma (OAG) group and 70 eyes in the highly myopic glaucoma (HMG) group.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!