Achieving and maintaining proper image registration accuracy is an open challenge of image-guided surgery. This work explores and assesses the efficacy of a registration sanity check method for augmented reality-guided navigation (AR-RSC), based on the visual inspection of virtual 3D models of landmarks. We analyze the AR-RSC sensitivity and specificity by recruiting 36 subjects to assess the registration accuracy of a set of 114 AR images generated from camera images acquired during an AR-guided orthognathic intervention. Translational or rotational errors of known magnitude up to ±1.5 mm/±15.5°, were artificially added to the image set in order to simulate different registration errors. This study analyses the performance of AR-RSC when varying (1) the virtual models selected for misalignment evaluation (e. g., the model of brackets, incisor teeth, and gingival margins in our experiment), (2) the type (translation/rotation) of registration error, and (3) the level of user experience in using AR technologies. Results show that: 1) the sensitivity and specificity of the AR-RSC depends on the virtual models (globally, a median true positive rate of up to 79.2% was reached with brackets, and a median true negative rate of up to 64.3% with incisor teeth), 2) there are error components that are more difficult to identify visually, 3) the level of user experience does not affect the method. In conclusion, the proposed AR-RSC, tested also in the operating room, could represent an efficient method to monitor and optimize the registration accuracy during the intervention, but special attention should be paid to the selection of the AR data chosen for the visual inspection of the registration accuracy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10896424PMC
http://dx.doi.org/10.1109/JTEHM.2023.3332088DOI Listing

Publication Analysis

Top Keywords

registration accuracy
16
virtual models
12
registration
8
registration sanity
8
sanity check
8
visual inspection
8
sensitivity specificity
8
incisor teeth
8
level user
8
user experience
8

Similar Publications

Purpose: The long scan times of quantitative MRI techniques make motion artifacts more likely. For MR-Fingerprinting-like approaches, this problem can be addressed with self-navigated retrospective motion correction based on reconstructions in a singular value decomposition (SVD) subspace. However, the SVD promotes high signal intensity in all tissues, which limits the contrast between tissue types and ultimately reduces the accuracy of registration.

View Article and Find Full Text PDF

In this work, a cost-effective, scalable pneumatic silicone actuator array is introduced, designed to dynamically conform to the user's skin and thereby alleviate localised pressure within a prosthetic socket. The appropriate constitutive models for developing a finite element representation of these actuators are systematically identified, parametrised, and validated. Employing this computational framework, the surface deformation fields induced by 270 variations in soft actuator array design parameters under realistic load conditions are examined, achieving predictive accuracies within 70 µm.

View Article and Find Full Text PDF

Background: We investigated the consistency and accuracy of the Index of Consciousness (IoC) and the Bispectral Index (BIS) in monitoring the sedative effect of ciprofol during the induction of general anesthesia. There is extensive literature that reports good consistency and correlations between the IoC1 and the BIS in reflecting the sedation levels induced by propofol and sevoflurane but not by ciprofol.

Objective: The aim was to compare the consistency and accuracy of the IoC and BIS in monitoring the sedative effect of ciprofol during the induction of general anesthesia.

View Article and Find Full Text PDF

Background: The ability to passively and continuously monitor coughing for prolonged periods of time would significantly improve cough management and research. To date there is no automated clinically validated cough monitor that can be routinely used in clinical care and research. Here we describe the validation of such an automated cough monitor.

View Article and Find Full Text PDF

Percutaneous coronary intervention (PCI) is a practical and effective method for treating coronary heart disease (CHD). This study aims to explore the influencing factors of major cardiovascular events (MACEs) and hospital readmission risk within one year following PCI treatment. Additionally, it seeks to assess the clinical value of Apolipoprotein B/Apolipoprotein A-I (ApoB/ApoA-I) in predicting the risk of one-year MACEs and readmission post-PCI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!